ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 300 → 500V ac, DIN Rail

RS kataloški broj:: 775-8043robna marka: ABBProizvođački broj:: 1SVR740794R3300 CM-PVS.41P
brand-logo
Prikaži sve u Monitoring Relays

Tehnička dokumentacija

Tehnički podaci

Brand

ABB

Monitoring Application

Phase, Voltage

Electrical Phase

3

Voltage Sensing Range

300 → 500V ac

Contact Configuration

DPDT

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Phase Sensitivity

Phase Failure, Phase Sequence

Time Delay

0.1 → 30 s, 0s

Frequency Sensing Range

45 → 65Hz

Series

CM-PVS

Maximum Voltage Sensed

500V ac

Operating Temperature Range

-25 → +60°C

Terminal Type

Push In

Standards Met

UL

Minimum Operating Temperature

-25°C

Width

22.5mm

Maximum Operating Temperature

+60°C

Dimensions

103.7 x 22.5 x 85.6mm

Current Range

2 → 4A

Height

85.6mm

Length

103.7mm

Minimum Voltage Sensed

300V ac

Zemlja podrijetla

Germany

Detalji o proizvodu

CM-PVS Three-Phase Monitoring Relays

The CM-PVS.x1 are monitoring relays for three-phase mains. They monitor the phase parameters phase sequence, phase failure, over- and undervoltage. The threshold values for over- and undervoltage are adjustable.

Informacije o stanju skladišta trenutno nisu dostupne.

Provjerite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

KM 804,60

Each (bez PDV-a)

KM 941,38

Each (s PDV-om)

ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 300 → 500V ac, DIN Rail

KM 804,60

Each (bez PDV-a)

KM 941,38

Each (s PDV-om)

ABB Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 300 → 500V ac, DIN Rail
Informacije o stanju skladišta trenutno nisu dostupne.

Kupujte na veliko

količinaJedinična cijena
1 - 4KM 804,60
5 - 9KM 774,32
10 - 24KM 765,67
25 - 49KM 750,53
50+KM 735,39

Tehnička dokumentacija

Tehnički podaci

Brand

ABB

Monitoring Application

Phase, Voltage

Electrical Phase

3

Voltage Sensing Range

300 → 500V ac

Contact Configuration

DPDT

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Phase Sensitivity

Phase Failure, Phase Sequence

Time Delay

0.1 → 30 s, 0s

Frequency Sensing Range

45 → 65Hz

Series

CM-PVS

Maximum Voltage Sensed

500V ac

Operating Temperature Range

-25 → +60°C

Terminal Type

Push In

Standards Met

UL

Minimum Operating Temperature

-25°C

Width

22.5mm

Maximum Operating Temperature

+60°C

Dimensions

103.7 x 22.5 x 85.6mm

Current Range

2 → 4A

Height

85.6mm

Length

103.7mm

Minimum Voltage Sensed

300V ac

Zemlja podrijetla

Germany

Detalji o proizvodu

CM-PVS Three-Phase Monitoring Relays

The CM-PVS.x1 are monitoring relays for three-phase mains. They monitor the phase parameters phase sequence, phase failure, over- and undervoltage. The threshold values for over- and undervoltage are adjustable.