Tehnička dokumentacija
Tehnički podaci
Brand
CrouzetMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
SPDT
Voltage Sensing Range
183 → 528V ac
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Asymmetry, Phase Failure, Phase Sequence
Time Delay
0.1 → 10s
Series
MWG
Height
92.6mm
Length
69mm
Minimum Voltage Sensed
183V ac
Operating Temperature Range
+50°C
Minimum Operating Temperature
-20°C
Width
17.5mm
Maximum Operating Temperature
+50°C
Dimensions
69 x 17.5 x 92.6mm
Maximum Voltage Sensed
528V ac
Zemlja podrijetla
Indonesia
Detalji o proizvodu
Multi Function Phase Control Relays 17.5mm - C-Lynx
3 phase network control relays monitor: the correct sequence of phases L1, L2, L3, the total phase failure - Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay and Asymmetry rate from 5% to 15% of Under Voltage Relay. LEDs are used for fault signalling, if a fault persists for longer than the threshold crossing delay configured by the operator, the output relay opens and the LED R is extinguished.
Informacije o stanju skladišta trenutno nisu dostupne.
Provjerite ponovno kasnije.
KM 372,02
Each (bez PDV-a)
KM 435,26
Each (s PDV-om)
1
KM 372,02
Each (bez PDV-a)
KM 435,26
Each (s PDV-om)
1
Kupujte na veliko
količina | Jedinična cijena |
---|---|
1 - 4 | KM 372,02 |
5 - 9 | KM 359,04 |
10 - 24 | KM 354,72 |
25 - 49 | KM 348,23 |
50+ | KM 339,58 |
Tehnička dokumentacija
Tehnički podaci
Brand
CrouzetMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
SPDT
Voltage Sensing Range
183 → 528V ac
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Asymmetry, Phase Failure, Phase Sequence
Time Delay
0.1 → 10s
Series
MWG
Height
92.6mm
Length
69mm
Minimum Voltage Sensed
183V ac
Operating Temperature Range
+50°C
Minimum Operating Temperature
-20°C
Width
17.5mm
Maximum Operating Temperature
+50°C
Dimensions
69 x 17.5 x 92.6mm
Maximum Voltage Sensed
528V ac
Zemlja podrijetla
Indonesia
Detalji o proizvodu
Multi Function Phase Control Relays 17.5mm - C-Lynx
3 phase network control relays monitor: the correct sequence of phases L1, L2, L3, the total phase failure - Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay and Asymmetry rate from 5% to 15% of Under Voltage Relay. LEDs are used for fault signalling, if a fault persists for longer than the threshold crossing delay configured by the operator, the output relay opens and the LED R is extinguished.