CAE Groupe HIFLEX-CY Series, 2x2 Cores, 0.5 mm², 20 AWG, Screened Shield, LiYCY-P Cable

RS kataloški broj:: 135-9257robna marka: CAE GroupeProizvođački broj:: MCP250
brand-logo

Tehnička dokumentacija

Tehnički podaci

Cross Sectional Area

0.5 mm²

Number of Cores

2x2

American Wire Gauge

20 AWG

Shield Type

Tinned Copper Braid

Sheath Colour

Grey

Cable Type

LiYCY-P

Outer Diameter

7.8mm

Outer Sheath Material

PVC

Cable Shape

Twisted Pair

Voltage Rating

300 V

Fire Behaviour

Flame Retardant

Minimum Operating Temperature

-30°C

Maximum Operating Temperature

+70°C

Standards Met

IEC 60228, IEC 60332-1, NF C 32-070/C2

Series

HIFLEX-CY

Core Strands

2/0.5 mm²

Zemlja podrijetla

Turkey

Detalji o proizvodu

Hi-FLEX-CY-P multipair cables with overall shielding (LiYCY-P)

Hi-FLEX®-CY-P cables are used for data transmission in highly electromagnetically disturbed environments. Applications include: Process controlled facilities, measurement and control technology and for fixed laying, flexible applications with undefined cable routing and no tensile stress.

Standards

IEC 60332-1

You may be interested in

Informacije o stanju skladišta trenutno nisu dostupne.

Provjerite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

KM 997,10

1 Reel of 50 Metres (bez PDV-a)

KM 1.166,61

1 Reel of 50 Metres (s PDV-om)

CAE Groupe HIFLEX-CY Series, 2x2 Cores, 0.5 mm², 20 AWG, Screened Shield, LiYCY-P Cable

KM 997,10

1 Reel of 50 Metres (bez PDV-a)

KM 1.166,61

1 Reel of 50 Metres (s PDV-om)

CAE Groupe HIFLEX-CY Series, 2x2 Cores, 0.5 mm², 20 AWG, Screened Shield, LiYCY-P Cable
Informacije o stanju skladišta trenutno nisu dostupne.
You may be interested in

Tehnička dokumentacija

Tehnički podaci

Cross Sectional Area

0.5 mm²

Number of Cores

2x2

American Wire Gauge

20 AWG

Shield Type

Tinned Copper Braid

Sheath Colour

Grey

Cable Type

LiYCY-P

Outer Diameter

7.8mm

Outer Sheath Material

PVC

Cable Shape

Twisted Pair

Voltage Rating

300 V

Fire Behaviour

Flame Retardant

Minimum Operating Temperature

-30°C

Maximum Operating Temperature

+70°C

Standards Met

IEC 60228, IEC 60332-1, NF C 32-070/C2

Series

HIFLEX-CY

Core Strands

2/0.5 mm²

Zemlja podrijetla

Turkey

Detalji o proizvodu

Hi-FLEX-CY-P multipair cables with overall shielding (LiYCY-P)

Hi-FLEX®-CY-P cables are used for data transmission in highly electromagnetically disturbed environments. Applications include: Process controlled facilities, measurement and control technology and for fixed laying, flexible applications with undefined cable routing and no tensile stress.