PAT Testers
PAT testers, or portable appliance testers, are specialised testing devices that are essential for checking electrical devices for faults in a wide range of working environments. PAT testing equipment will provide a pass or fail for the appliance you are testing immediately, so you know it's safe to use. By using the appropriate type of PAT tester, you can identify potential electrical risks, miti...
Prikazuje se 1-20 od 127 proizvoda
Martindale
Pass/Fail PAT
Class I, Class II
Automatic
-
-
-
HPAT400/2
Battery
-
HPAT400/2
AA
600 (Test)
90 x 54 x 210mm
700g
210mm
90mm
+40°C
-
54mm
-
-10°C
Martindale
PAT Tester
Class I, Class II
Automatic, Manual
-
-
-
HPAT600/2
Battery
-
HPAT600/2
AA
600 (Test)
90 x 54 x 210mm
700g
210mm
90mm
+40°C
1.2V
54mm
-
-10°C
Martindale
Pass/Fail PAT
Class I, Class II
Automatic
-
-
-
HPAT500/2
Battery
-
HPAT500/2
AA
600 (Test)
90 x 54 x 210mm
700g
210mm
90mm
+40°C
1.2V
54mm
-
-10°C
Chauvin Arnoux
Machine and Electrical Switchboard Testers
Class I, Class II
Automatic, Manual
Yes
-
Yes
CA 6161
Mains
Type F - Schuko plug
CA 6161
-
-
340 x 405 x 194mm
9kg
194mm
340mm
+45°C
3000V
405mm
40V
0°C
Chauvin Arnoux
Machine and Electrical Switchboard Testers
Class I, Class II
Automatic, Manual
Yes
-
Yes
CA 6163
Mains
Type F - Schuko plug
CA 6163
-
-
340 x 405 x 194mm
15kg
194mm
340mm
+45°C
5350V
405mm
40V
0°C
Chauvin Arnoux
Machine and Electrical Switchboard Testers
Class I, Class II
Automatic, Manual
Yes
RSCAL
Yes
CA 6163
Mains
Type F - Schuko plug
CA 6163
-
-
340 x 405 x 194mm
15kg
194mm
340mm
+45°C
5350V
405mm
40V
0°C
Chauvin Arnoux
Machine and Electrical Switchboard Testers
Class I, Class II
Automatic, Manual
Yes
UKAS
Yes
CA 6163
Mains
Type F - Schuko plug
CA 6163
-
-
340 x 405 x 194mm
15kg
194mm
340mm
+45°C
5350V
405mm
40V
0°C
Fluke
PAT Tester Kit
Continuity, Current, Earth, Insulation, RCD, Voltage
Automatic, Manual
Yes
-
No
6500-2 UK
Mains
-
6500-2 UK
-
-
200 x 275 x 114mm
3.1kg
200mm
275mm
-
230V
114mm
-
-
Gossen Metrawatt
Medical Safety Tester
Insulation Resistance, Leakage Current
Automatic
Yes
-
-
SECULIFE ST PRO
Mains
-
SECULIFE ST PRO
-
-
-
-
-
-
-
-
-
-
-
Gossen Metrawatt
Advanced PAT
AC and DC Patient Leakage Current, Class I, Class II, Class IT, Contact Current, Continuity, Current, Differential Current Measurement, Direct Measurement, Earth, Earth Leakage Current, Equivalent Leakage Current Procedure, Insulation, Insulation Resistance, Protective Conductor Resistance, RCD, Voltage
Automatic, Manual
Yes
DAkkS
Yes
SECUTEST LEMONGREEN
Mains
-
SECUTEST LEMONGREEN
-
-
295 x 145 x 150mm
2.5kg
145mm
295mm
+40°C
230V
-
-
-
Gossen Metrawatt
Medical Safety Tester
Class I, Class II
Automatic, Manual
-
UKAS
-
SECUTEST S2 N+10
Mains
-
-
-
-
292 x 130 x 243mm
4.5kg
243mm
292mm
-
230V
130mm
110V
-
Martindale
Advanced PAT
Class I, Class II
Automatic, Manual
-
RSCAL
-
HPAT600/2
Battery
-
HPAT600/2
AA
600 (Test)
90 x 54 x 210mm
700g
210mm
90mm
+40°C
1.2V
54mm
-
-10°C
Martindale
Advanced PAT
Class I, Class II
Automatic, Manual
-
UKAS
-
HPAT600/2
Battery
-
HPAT600/2
AA
600 (Test)
90 x 54 x 210mm
700g
210mm
90mm
+40°C
1.2V
54mm
-
-10°C
Martindale
Insulation Tester Kit
Class I, Class II
Automatic
No
-
No
HPAT600KIT1-2
Battery, Mains
-
HPAT600KIT1-2
-
-
-
-
-
-
-
-
-
-
-
...