Dold Soft Starter, 1.5 kW, 3 kW, 230 V ac, 400 V ac, 1 Phase, IP30

RS kataloški broj:: 240-9140robna marka: DoldProizvođački broj:: BA9010 3AC230/400V 1.5/3kW
brand-logo
Prikaži sve u Motor Starters

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Dold

Power Rating

1.5 kW, 3 kW

Motor Starter Type

Soft Start

Voltage Rating

230 V ac, 400 V ac

Phase

1

IP Rating

IP30

Overall Length

121mm

Overall Width

45mm

Overall Depth

74mm

Series

BA9010

Zemlja podrijetla

Germany

Detalji o proizvodu

Soft starter, BA9010

Warning


If devices are used in 230 V three-phase networks, the next higher power stage must be used for a given motor power, because the motor current determines the overall size of the device.
The starting current in the network cannot be lowered with these devices. In order to achieve this simultaneously with torque reduction, the BA9026 must be used, for example.
The BA9010 must not be operated with a capacitive load (e.g. reactive power compensation) at the output.
In the decoupled state (without load), the starting behaviour is not particularly smooth.

Možda će vas zanimati

€ 379,47

€ 379,47 komadno (bez PDV-a)

€ 474,34

€ 474,34 komadno (s PDV-om)

Dold Soft Starter, 1.5 kW, 3 kW, 230 V ac, 400 V ac, 1 Phase, IP30

€ 379,47

€ 379,47 komadno (bez PDV-a)

€ 474,34

€ 474,34 komadno (s PDV-om)

Dold Soft Starter, 1.5 kW, 3 kW, 230 V ac, 400 V ac, 1 Phase, IP30

Informacije o stanju skladišta trenutno nisu dostupne.

Informacije o stanju skladišta trenutno nisu dostupne.

Možda će vas zanimati

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Dold

Power Rating

1.5 kW, 3 kW

Motor Starter Type

Soft Start

Voltage Rating

230 V ac, 400 V ac

Phase

1

IP Rating

IP30

Overall Length

121mm

Overall Width

45mm

Overall Depth

74mm

Series

BA9010

Zemlja podrijetla

Germany

Detalji o proizvodu

Soft starter, BA9010

Warning


If devices are used in 230 V three-phase networks, the next higher power stage must be used for a given motor power, because the motor current determines the overall size of the device.
The starting current in the network cannot be lowered with these devices. In order to achieve this simultaneously with torque reduction, the BA9026 must be used, for example.
The BA9010 must not be operated with a capacitive load (e.g. reactive power compensation) at the output.
In the decoupled state (without load), the starting behaviour is not particularly smooth.