Fluke 8846A Bench Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max - UKAS Calibrated

RS kataloški broj:: 625-0469robna marka: FlukeProizvođački broj:: 8846A
brand-logo
Prikaži sve u Multimetri

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Fluke

Multimeter Type

Bench

Model Number p

8846A

Display Type

Digital

Calibrated

UKAS

Functions Measured

AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature

Absolute Maximum AC Current Measurement

10A ac

Absolute Maximum AC Voltage Measurement

1000V ac

Absolute Maximum DC Current Measurement

10A dc

Absolute Maximum Resistance Measurement

1GΩ

Absolute Maximum DC Voltage Measurement

1000V dc

Absolute Maximum Capacitance Measurement

100mF

Absolute Maximum Temperature Measurement

+600°C

Maximum Frequency

300kHz

AC Current Measurement Resolution

0.0001µA ac

DC Current Measurement Resolution

0.0001µA dc

AC Voltage Measurement Resolution

0.0001mV ac

DC Voltage Measurement Resolution

0.0001mV dc

Resistance Measurement Resolution

10µΩ

Safety Category Level

CAT I, CAT II

Capacitance Measurement Resolution

1pF

Temperature Measurement Resolution

0.001°C

Best AC Current Accuracy

±0.35% + 0.7

Width

217mm

Dimensions

297 x 217 x 88mm

Best Temperature Measurement Accuracy

±0.22 %

Best AC Voltage Accuracy

±4% + 0.375

Best Capacitance Measurement Accuracy

±4.2 %

Minimum Operating Temperature

0°C

Height

88mm

Weight

3.6kg

Best DC Current Accuracy

±0.15% + 0.008

Safety Category Voltage

600 V, 1000V

Best Resistance Measurement Accuracy

±2% + 0.01

Length

297mm

Maximum Operating Temperature

+55°C

Best DC Voltage Accuracy

±0.0041% + 0.001

Zemlja podrijetla

United States

Detalji o proizvodu

8845A & 8846A 6.5 Digit Precision Multimeter

The Fluke 8845A and 8846A are 6.5 digit precision multimeters that are able to handle measurements on the bench or in a system. Both feature a unique graphical display that can reveal signal quality issues like drift, intermittant and stability by using the analytical functions. The 8846A increases basic Vdc accuracy to 0.0025% plus adds measurements like capacitance, RTD temperature and dB.

Supplied with

• TL71 test lead set
• FlukeView® Forms – Basic for 8845A/8846A
• Mains lead
• Spare mains fuse
• Programmer & users manuals (CD-ROM)

Informacije o stanju skladišta trenutno nisu dostupne.

Provjerite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

P.O.A.

Fluke 8846A Bench Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max - UKAS Calibrated

Calibration type

P.O.A.

Fluke 8846A Bench Digital Multimeter, True RMS, 10A ac Max, 10A dc Max, 1000V ac Max - UKAS Calibrated
Informacije o stanju skladišta trenutno nisu dostupne.

Calibration type

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Fluke

Multimeter Type

Bench

Model Number p

8846A

Display Type

Digital

Calibrated

UKAS

Functions Measured

AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature

Absolute Maximum AC Current Measurement

10A ac

Absolute Maximum AC Voltage Measurement

1000V ac

Absolute Maximum DC Current Measurement

10A dc

Absolute Maximum Resistance Measurement

1GΩ

Absolute Maximum DC Voltage Measurement

1000V dc

Absolute Maximum Capacitance Measurement

100mF

Absolute Maximum Temperature Measurement

+600°C

Maximum Frequency

300kHz

AC Current Measurement Resolution

0.0001µA ac

DC Current Measurement Resolution

0.0001µA dc

AC Voltage Measurement Resolution

0.0001mV ac

DC Voltage Measurement Resolution

0.0001mV dc

Resistance Measurement Resolution

10µΩ

Safety Category Level

CAT I, CAT II

Capacitance Measurement Resolution

1pF

Temperature Measurement Resolution

0.001°C

Best AC Current Accuracy

±0.35% + 0.7

Width

217mm

Dimensions

297 x 217 x 88mm

Best Temperature Measurement Accuracy

±0.22 %

Best AC Voltage Accuracy

±4% + 0.375

Best Capacitance Measurement Accuracy

±4.2 %

Minimum Operating Temperature

0°C

Height

88mm

Weight

3.6kg

Best DC Current Accuracy

±0.15% + 0.008

Safety Category Voltage

600 V, 1000V

Best Resistance Measurement Accuracy

±2% + 0.01

Length

297mm

Maximum Operating Temperature

+55°C

Best DC Voltage Accuracy

±0.0041% + 0.001

Zemlja podrijetla

United States

Detalji o proizvodu

8845A & 8846A 6.5 Digit Precision Multimeter

The Fluke 8845A and 8846A are 6.5 digit precision multimeters that are able to handle measurements on the bench or in a system. Both feature a unique graphical display that can reveal signal quality issues like drift, intermittant and stability by using the analytical functions. The 8846A increases basic Vdc accuracy to 0.0025% plus adds measurements like capacitance, RTD temperature and dB.

Supplied with

• TL71 test lead set
• FlukeView® Forms – Basic for 8845A/8846A
• Mains lead
• Spare mains fuse
• Programmer & users manuals (CD-ROM)