Chauvin Arnoux P01654621 Temperature Calibrator

RS kataloški broj:: 758-8939robna marka: Chauvin ArnouxProizvođački broj:: P01654621
brand-logo
Prikaži sve u Temperature Calibrators

Tehnička dokumentacija

Tehnički podaci

Resolution

0.01 mV

Calibrator Type

Thermocouple Calibrator

Best Accuracy

± 0.3°C

Thermocouple Type

B, E, J, K, N, R, S, T

Temperature Scale

Centigrade

B Type Thermocouple Maximum Temperature

+1800°C

B Type Thermocouple Minimum Temperature

+600°C

E Type Thermocouple Maximum Temperature

+950°C

E Type Thermocouple Minimum Temperature

-200°C

J Type Thermocouple Maximum Temperature

+1200°C

K Type Thermocouple Maximum Temperature

+1370°C

K Type Thermocouple Minimum Temperature

-200°C

Model Number p

CA 1621

R Type Thermocouple Maximum Temperature

+1750°C

T Type Thermocouple Maximum Temperature

+400°C

T Type Thermocouple Minimum Temperature

-200°C

E Type Thermocouple Temperature Range

-200 → +950 °C

Height

45mm

Weight

472g

S Type Thermocouple Minimum Temperature

-20°C

S Type Thermocouple Temperature Range

-20 → +1750 °C

S Type Thermocouple Maximum Temperature

+1750°C

T Type Thermocouple Temperature Range

-200 → +400 °C

J Type Thermocouple Temperature Range

-200 → +1200 °C

R Type Thermocouple Temperature Range

-20 → +1750 °C

Dimensions

205 x 97 x 45mm

Width

97mm

Length

205mm

R Type Thermocouple Minimum Temperature

-20°C

B Type Thermocouple Temperature Range

+600 → +1800 °C

K Type Thermocouple Temperature Range

-200 → +1370 °C

Zemlja podrijetla

China

Detalji o proizvodu

Chauvin Arnoux Calibrators CA1621, CA1623 & CA1631

These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation and measurement. They simulate a signal or generate a quantity with precisely-defined values, for applying upstream of the measurement chain, and measure the signal. The CA1621, CA1623 & CA1631 calibrators are designed to accurately measure, generate or simulate all the low-level signals encountered in industry. Applications include maintenance operations, commissioning, verification, on-line calibration and adjustment and testing of measurement lines.

You may be interested in
RS PRO Thermocouple Calibrator
P.O.A.Each (bez PDV-a)

Informacije o stanju skladišta trenutno nisu dostupne.

Provjerite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

P.O.A.

Chauvin Arnoux P01654621 Temperature Calibrator

Calibration type

P.O.A.

Chauvin Arnoux P01654621 Temperature Calibrator
Informacije o stanju skladišta trenutno nisu dostupne.

Calibration type

You may be interested in
RS PRO Thermocouple Calibrator
P.O.A.Each (bez PDV-a)

Tehnička dokumentacija

Tehnički podaci

Resolution

0.01 mV

Calibrator Type

Thermocouple Calibrator

Best Accuracy

± 0.3°C

Thermocouple Type

B, E, J, K, N, R, S, T

Temperature Scale

Centigrade

B Type Thermocouple Maximum Temperature

+1800°C

B Type Thermocouple Minimum Temperature

+600°C

E Type Thermocouple Maximum Temperature

+950°C

E Type Thermocouple Minimum Temperature

-200°C

J Type Thermocouple Maximum Temperature

+1200°C

K Type Thermocouple Maximum Temperature

+1370°C

K Type Thermocouple Minimum Temperature

-200°C

Model Number p

CA 1621

R Type Thermocouple Maximum Temperature

+1750°C

T Type Thermocouple Maximum Temperature

+400°C

T Type Thermocouple Minimum Temperature

-200°C

E Type Thermocouple Temperature Range

-200 → +950 °C

Height

45mm

Weight

472g

S Type Thermocouple Minimum Temperature

-20°C

S Type Thermocouple Temperature Range

-20 → +1750 °C

S Type Thermocouple Maximum Temperature

+1750°C

T Type Thermocouple Temperature Range

-200 → +400 °C

J Type Thermocouple Temperature Range

-200 → +1200 °C

R Type Thermocouple Temperature Range

-20 → +1750 °C

Dimensions

205 x 97 x 45mm

Width

97mm

Length

205mm

R Type Thermocouple Minimum Temperature

-20°C

B Type Thermocouple Temperature Range

+600 → +1800 °C

K Type Thermocouple Temperature Range

-200 → +1370 °C

Zemlja podrijetla

China

Detalji o proizvodu

Chauvin Arnoux Calibrators CA1621, CA1623 & CA1631

These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation and measurement. They simulate a signal or generate a quantity with precisely-defined values, for applying upstream of the measurement chain, and measure the signal. The CA1621, CA1623 & CA1631 calibrators are designed to accurately measure, generate or simulate all the low-level signals encountered in industry. Applications include maintenance operations, commissioning, verification, on-line calibration and adjustment and testing of measurement lines.

You may be interested in
RS PRO Thermocouple Calibrator
P.O.A.Each (bez PDV-a)