Dold Soft Starter, 1.5 kW, 3 kW, 230 V ac, 400 V ac, 1 Phase, IP30

RS kataloški broj:: 240-9140brend: DoldProizvođački broj:: BA9010 3AC230/400V 1.5/3kW
brand-logo
Prikaži sve u Motor Starters

Tehnička dokumentacija

Tehnički podaci

Brand

Dold

Power Rating

1.5 kW, 3 kW

Motor Starter Type

Soft Start

Voltage Rating

230 V ac, 400 V ac

Phase

1

IP Rating

IP30

Overall Length

121mm

Overall Width

45mm

Series

BA9010

Overall Depth

74mm

Zemlja podrijetla

Germany

Detalji o proizvodu

Soft starter, BA9010

Warning


If devices are used in 230 V three-phase networks, the next higher power stage must be used for a given motor power, because the motor current determines the overall size of the device.
The starting current in the network cannot be lowered with these devices. In order to achieve this simultaneously with torque reduction, the BA9026 must be used, for example.
The BA9010 must not be operated with a capacitive load (e.g. reactive power compensation) at the output.
In the decoupled state (without load), the starting behaviour is not particularly smooth.

Možda će vas interesovati
Informacije o stanju skladišta trenutno nisu dostupne.

RSD 50.584

RSD 50.584 Each (bez PDV-a)

RSD 60.701

RSD 60.701 Each (s PDV-om)

Dold Soft Starter, 1.5 kW, 3 kW, 230 V ac, 400 V ac, 1 Phase, IP30

RSD 50.584

RSD 50.584 Each (bez PDV-a)

RSD 60.701

RSD 60.701 Each (s PDV-om)

Dold Soft Starter, 1.5 kW, 3 kW, 230 V ac, 400 V ac, 1 Phase, IP30
Informacije o stanju skladišta trenutno nisu dostupne.

Informacije o stanju skladišta trenutno nisu dostupne.

Proverite ponovno kasnije.

Možda će vas interesovati

Tehnička dokumentacija

Tehnički podaci

Brand

Dold

Power Rating

1.5 kW, 3 kW

Motor Starter Type

Soft Start

Voltage Rating

230 V ac, 400 V ac

Phase

1

IP Rating

IP30

Overall Length

121mm

Overall Width

45mm

Series

BA9010

Overall Depth

74mm

Zemlja podrijetla

Germany

Detalji o proizvodu

Soft starter, BA9010

Warning


If devices are used in 230 V three-phase networks, the next higher power stage must be used for a given motor power, because the motor current determines the overall size of the device.
The starting current in the network cannot be lowered with these devices. In order to achieve this simultaneously with torque reduction, the BA9026 must be used, for example.
The BA9010 must not be operated with a capacitive load (e.g. reactive power compensation) at the output.
In the decoupled state (without load), the starting behaviour is not particularly smooth.