Dehn, DFL Surge Arrester 255 V ac Maximum Voltage Rating 3kA Maximum Surge Current Surge Arrester

RS kataloški broj:: 768-1805robna marka: DehnProizvođački broj:: DFL M 255
brand-logo
Prikaži sve u Surge Suppressor Units

Tehnička dokumentacija

Tehnički podaci

Brand

Dehn

Suppressor Type

Surge Arrester

Maximum Voltage Rating

255 V ac

Mounting Type

Flush Mount

Maximum Surge Current

3kA

Series

DFL

Length

30mm

Depth

11mm

Height

50mm

Dimensions

30 x 11 x 50mm

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

+40°C

Zemlja podrijetla

Germany

Detalji o proizvodu

DEHNflex with Acoustic Fault Indication

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Informacije o stanju skladišta trenutno nisu dostupne.

Provjerite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

€ 224,00

Each (bez PDV-a)

€ 262,08

Each (s PDV-om)

Dehn, DFL Surge Arrester 255 V ac Maximum Voltage Rating 3kA Maximum Surge Current Surge Arrester

€ 224,00

Each (bez PDV-a)

€ 262,08

Each (s PDV-om)

Dehn, DFL Surge Arrester 255 V ac Maximum Voltage Rating 3kA Maximum Surge Current Surge Arrester
Informacije o stanju skladišta trenutno nisu dostupne.

Kupujte na veliko

količinaJedinična cijena
1 - 4€ 224,00
5 - 9€ 218,00
10 - 19€ 215,00
20 - 29€ 204,00
30+€ 189,00

Tehnička dokumentacija

Tehnički podaci

Brand

Dehn

Suppressor Type

Surge Arrester

Maximum Voltage Rating

255 V ac

Mounting Type

Flush Mount

Maximum Surge Current

3kA

Series

DFL

Length

30mm

Depth

11mm

Height

50mm

Dimensions

30 x 11 x 50mm

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

+40°C

Zemlja podrijetla

Germany

Detalji o proizvodu

DEHNflex with Acoustic Fault Indication

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.