Tehnička dokumentacija
Tehnički podaci
Brand
HoneywellActuator Type
Plunger
Pole and Throw Configuration
SPDT
Normal State Configuration
NO/NC
IP Rating
IP66, IP67
Maximum Current
4A
Housing Material
Die Cast Zinc
Maximum AC Voltage
250V
Connection Type
Cable
Series
GXA
Action Type
Snap Action
Length
102.9mm
Depth
62.4mm
Width
42mm
Maximum Operating Temperature
+75°C
Hazardous Area Certification
ATEX
Minimum Operating Temperature
-20°C
Zemlja podrijetla
United Kingdom
Detalji o proizvodu
Honeywell GXA Limit Switches
The GXA series from Honeywell forms part of the wider GXS range of flame proof limit switches. They are compact with a very small footprint, making them ideal for use in applications where space is at a premium. They can be used in potentially explosive atmospheres, meeting 94/9/EC, commonly referred to as the ATEX Directive.
Warning
GXA limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Standards
ATEX (CE), IEC Ex
Shock resistant to IEC 60068-2-27 standard.
Vibration resistant to IEC 60068-2-6 standard.
II 2 G Ex d IIC T6, II 2 D Ex tD A21 IP66 T85°C.
KEMA 00 ATEX 2103 X, IEC Ex KEM 10.0039X.
Conforms to EN60079-0, EN60079-1, EN61241-0, EN61241-1.
CE marked.
Informacije o stanju skladišta trenutno nisu dostupne.
Provjerite ponovno kasnije.
P.O.A.
1
P.O.A.
1
Tehnička dokumentacija
Tehnički podaci
Brand
HoneywellActuator Type
Plunger
Pole and Throw Configuration
SPDT
Normal State Configuration
NO/NC
IP Rating
IP66, IP67
Maximum Current
4A
Housing Material
Die Cast Zinc
Maximum AC Voltage
250V
Connection Type
Cable
Series
GXA
Action Type
Snap Action
Length
102.9mm
Depth
62.4mm
Width
42mm
Maximum Operating Temperature
+75°C
Hazardous Area Certification
ATEX
Minimum Operating Temperature
-20°C
Zemlja podrijetla
United Kingdom
Detalji o proizvodu
Honeywell GXA Limit Switches
The GXA series from Honeywell forms part of the wider GXS range of flame proof limit switches. They are compact with a very small footprint, making them ideal for use in applications where space is at a premium. They can be used in potentially explosive atmospheres, meeting 94/9/EC, commonly referred to as the ATEX Directive.
Warning
GXA limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Standards
ATEX (CE), IEC Ex
Shock resistant to IEC 60068-2-27 standard.
Vibration resistant to IEC 60068-2-6 standard.
II 2 G Ex d IIC T6, II 2 D Ex tD A21 IP66 T85°C.
KEMA 00 ATEX 2103 X, IEC Ex KEM 10.0039X.
Conforms to EN60079-0, EN60079-1, EN61241-0, EN61241-1.
CE marked.