RS PRO Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 10 → 30V dc Supply

RS kataloški broj:: 218-4469robna marka: RS PRO
brand-logo
Prikaži sve u Signal Conditioners

Tehnička dokumentacija

Tehnički podaci

Brand

RS Pro

Module Type

Signal Isolator

Input Signal Type

Current, Voltage

Output Signal Type

Current, Voltage

Input Range

0 → 20 mA, -250 → +250V dc

Output Range

0 → 10 mA, 0 → 10V dc

Supply Voltage

10 → 30V dc

Mounting Type

DIN Rail Mount

Operating Temperature Range

0 → +50°C

Series

9100

Minimum Operating Temperature

0°C

Maximum Operating Temperature

+50°C

Termination

Screw

Zemlja podrijetla

United Kingdom

Detalji o proizvodu

24Vdc Trip Amplifiers, Signal Isolator/Converters

Symmetric DIN rail mounting units with finger protected terminals designed for use in process control and instrumentation applications. Single or dual level trip amplifiers from a single Input.Each trip can be arranged so that the alarm condition can be above (high trip) or below (low trip) the set point, and that the relay can be either normally energised to de-energise in the alarm condition (fail-safe), or normally de-energised to energise in the alarm condition (non fail-safe).,signal Isolators/converter; this unit conditions the signal before sending it through an opto-isolated hybrid circuit. Input and output stages are power from separate secondaries of the dc/dc inverter to provide 3 port isolation

Informacije o stanju skladišta trenutno nisu dostupne.

Provjerite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

€ 348,00

Each (bez PDV-a)

€ 407,16

Each (s PDV-om)

RS PRO Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 10 → 30V dc Supply

€ 348,00

Each (bez PDV-a)

€ 407,16

Each (s PDV-om)

RS PRO Signal Conditioner, Current, Voltage Input, Current, Voltage Output, 10 → 30V dc Supply
Informacije o stanju skladišta trenutno nisu dostupne.

Tehnička dokumentacija

Tehnički podaci

Brand

RS Pro

Module Type

Signal Isolator

Input Signal Type

Current, Voltage

Output Signal Type

Current, Voltage

Input Range

0 → 20 mA, -250 → +250V dc

Output Range

0 → 10 mA, 0 → 10V dc

Supply Voltage

10 → 30V dc

Mounting Type

DIN Rail Mount

Operating Temperature Range

0 → +50°C

Series

9100

Minimum Operating Temperature

0°C

Maximum Operating Temperature

+50°C

Termination

Screw

Zemlja podrijetla

United Kingdom

Detalji o proizvodu

24Vdc Trip Amplifiers, Signal Isolator/Converters

Symmetric DIN rail mounting units with finger protected terminals designed for use in process control and instrumentation applications. Single or dual level trip amplifiers from a single Input.Each trip can be arranged so that the alarm condition can be above (high trip) or below (low trip) the set point, and that the relay can be either normally energised to de-energise in the alarm condition (fail-safe), or normally de-energised to energise in the alarm condition (non fail-safe).,signal Isolators/converter; this unit conditions the signal before sending it through an opto-isolated hybrid circuit. Input and output stages are power from separate secondaries of the dc/dc inverter to provide 3 port isolation