Telemecanique Sensors XY2CE Rope Pull Switch, 70m, 2NO/2NC

RS kataloški broj:: 130-0880robna marka: Telemecanique SensorsProizvođački broj:: XY2CE2A290
brand-logo
Prikaži sve u Rope Pull Switches

Tehnička dokumentacija

Tehnički podaci

Normal State Configuration

2NO/2NC

Cable Length

70m

IP Rating

IP66

Number of Poles

DPST

Series

XY2CE

Range

Preventa XY2

Length

229mm

Width

105mm

Depth

142mm

Housing Material

Stainless Steel

Hazardous Area Certification

ATEX

Minimum Operating Temperature

-25°C

Standards Met

CCC, CSA, CSA C 22-2, EAC, EN/IEC 60947-5-5, UL (NISD), UL 508

Conduit Entry

M20

Maximum AC Voltage

240V

Maximum Operating Temperature

+70°C

Maximum DC Voltage

250V

Dimensions

229 x 105 x 142mm

Zemlja podrijetla

Morocco

Detalji o proizvodu

Telemecanique XY2CE & XY2CB Emergency Stop Rope Pull Switches

These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the trip wire breaking.

Standards

EN/ISO 13850:2006

Informacije o stanju skladišta trenutno nisu dostupne.

Provjerite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

€ 499,00

Each (bez PDV-a)

€ 583,83

Each (s PDV-om)

Telemecanique Sensors XY2CE Rope Pull Switch, 70m, 2NO/2NC

€ 499,00

Each (bez PDV-a)

€ 583,83

Each (s PDV-om)

Telemecanique Sensors XY2CE Rope Pull Switch, 70m, 2NO/2NC
Informacije o stanju skladišta trenutno nisu dostupne.

Tehnička dokumentacija

Tehnički podaci

Normal State Configuration

2NO/2NC

Cable Length

70m

IP Rating

IP66

Number of Poles

DPST

Series

XY2CE

Range

Preventa XY2

Length

229mm

Width

105mm

Depth

142mm

Housing Material

Stainless Steel

Hazardous Area Certification

ATEX

Minimum Operating Temperature

-25°C

Standards Met

CCC, CSA, CSA C 22-2, EAC, EN/IEC 60947-5-5, UL (NISD), UL 508

Conduit Entry

M20

Maximum AC Voltage

240V

Maximum Operating Temperature

+70°C

Maximum DC Voltage

250V

Dimensions

229 x 105 x 142mm

Zemlja podrijetla

Morocco

Detalji o proizvodu

Telemecanique XY2CE & XY2CB Emergency Stop Rope Pull Switches

These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the trip wire breaking.

Standards

EN/ISO 13850:2006