Tehnička dokumentacija
Tehnički podaci
Brand
CastleMaximum Sound Level
140dB
Minimum Sound Level
35dB
Resolution
0.1 dB
Accuracy Class
IEC 61672-1:2002 Class 2
DOSE Measurement
No
Weighting
A, C
Display Type
LCD
Battery Type
9V PP3
Fast/Slow Time Averaging
Both
Data Logging
No
Maximum Frequency
8kHz
Maximum Operating Temperature
+50°C
Minimum Frequency
20 Hz
Minimum Operating Temperature
-10°C
Model Number p
Sonus GA216B Class 2
Zemlja podrijetla
United Kingdom
Detalji o proizvodu
Castle GA216B Sonus Class 2 Sound Pressure Level Meter (non data logging version)
Castle GA216B is designed for general survey health & safety and engineering applications by industrial safety officers, occupational nurses, fire alarm installation & test engineers and industrial engineers. It gives clear results which meet the requirements of international standards. GA216B is a Sonus range entry-level Type 2 sound meter fully compliant with IEC 61672-1:2002. The difference between Type 1 and Type 2 is in the tolerance, for example: at reference frequency 1kHz, tolerance is ±1.1dB (Type 1) and ±1.4dB (Type 2); at 20Hz, tolerance is ±2.5dB (Class 1) and ±3.5dB (Class 2). Compliance with IEC 61672-1:2002 Class 2 and IEC 60651:1979 Type 2 is necessary for carrying out most noise assessment tasks in industry.
Standards
IEC 61672-1:2002 Class 2, IEC 60651: 1979 Type 2
Informacije o stanju skladišta trenutno nisu dostupne.
Proverite ponovno kasnije.
P.O.A.
Calibration type
Bez kalibracije
1
P.O.A.
Calibration type
Bez kalibracije
1
Tehnička dokumentacija
Tehnički podaci
Brand
CastleMaximum Sound Level
140dB
Minimum Sound Level
35dB
Resolution
0.1 dB
Accuracy Class
IEC 61672-1:2002 Class 2
DOSE Measurement
No
Weighting
A, C
Display Type
LCD
Battery Type
9V PP3
Fast/Slow Time Averaging
Both
Data Logging
No
Maximum Frequency
8kHz
Maximum Operating Temperature
+50°C
Minimum Frequency
20 Hz
Minimum Operating Temperature
-10°C
Model Number p
Sonus GA216B Class 2
Zemlja podrijetla
United Kingdom
Detalji o proizvodu
Castle GA216B Sonus Class 2 Sound Pressure Level Meter (non data logging version)
Castle GA216B is designed for general survey health & safety and engineering applications by industrial safety officers, occupational nurses, fire alarm installation & test engineers and industrial engineers. It gives clear results which meet the requirements of international standards. GA216B is a Sonus range entry-level Type 2 sound meter fully compliant with IEC 61672-1:2002. The difference between Type 1 and Type 2 is in the tolerance, for example: at reference frequency 1kHz, tolerance is ±1.1dB (Type 1) and ±1.4dB (Type 2); at 20Hz, tolerance is ±2.5dB (Class 1) and ±3.5dB (Class 2). Compliance with IEC 61672-1:2002 Class 2 and IEC 60651:1979 Type 2 is necessary for carrying out most noise assessment tasks in industry.
Standards
IEC 61672-1:2002 Class 2, IEC 60651: 1979 Type 2