Tehnička dokumentacija
Tehnički podaci
Brand
Phoenix ContactProperties Measured
Current, Resistance, TC, Voltage
Display Type
LCD
Cutout Height
45mm
Cutout Width
92mm
Number Of Digits
5
Depth
16.7mm
Minimum Temperature
-20°C
Maximum Temperature
+60°C
Measurement Range
0 → 20 mA, -200 → +1100 (Thermometer) °C, -200 → +2495 (Thermocouple) °C, -30 → +30 V, 30 → 3000 Ω
Approvals
CE Compliant, CSA GP, GL EMC 1 C, IEC 61326, UL Recognised 61010
Series
FA MCR-D-TUI-UI-2REL-UP
Meter Type
Electrical
Minimum Measurement
-30 V, 0 mA, 30 Ω, -200 (Thermocouple) °C, -200 (Thermometer) °C
Zemlja podrijetla
Germany
Detalji o proizvodu
Multifunctional Process Indicator
Professional range of digital display multifunctional process indicators from Phoenix Contact. The Process indicator is designed for monitoring and displaying analogue measurement data. With the universal inputs permit connection of current, voltage, RTDs and TCs. Limit values can be monitored and relays can be switched. The analogue output allows you to transmit process signals. All models are highly reliable and excellent quality.
Informacije o stanju skladišta trenutno nisu dostupne.
Provjerite ponovno kasnije.
P.O.A.
1
P.O.A.
1
Tehnička dokumentacija
Tehnički podaci
Brand
Phoenix ContactProperties Measured
Current, Resistance, TC, Voltage
Display Type
LCD
Cutout Height
45mm
Cutout Width
92mm
Number Of Digits
5
Depth
16.7mm
Minimum Temperature
-20°C
Maximum Temperature
+60°C
Measurement Range
0 → 20 mA, -200 → +1100 (Thermometer) °C, -200 → +2495 (Thermocouple) °C, -30 → +30 V, 30 → 3000 Ω
Approvals
CE Compliant, CSA GP, GL EMC 1 C, IEC 61326, UL Recognised 61010
Series
FA MCR-D-TUI-UI-2REL-UP
Meter Type
Electrical
Minimum Measurement
-30 V, 0 mA, 30 Ω, -200 (Thermocouple) °C, -200 (Thermometer) °C
Zemlja podrijetla
Germany
Detalji o proizvodu
Multifunctional Process Indicator
Professional range of digital display multifunctional process indicators from Phoenix Contact. The Process indicator is designed for monitoring and displaying analogue measurement data. With the universal inputs permit connection of current, voltage, RTDs and TCs. Limit values can be monitored and relays can be switched. The analogue output allows you to transmit process signals. All models are highly reliable and excellent quality.