Chauvin Arnoux CA 1631 Current & Voltage Calibrator, Max Voltage 20V dc, Max Current 24mA
Tehnička dokumentacija
Tehnički podaci
Proizvođač
Chauvin ArnouxAbsolute Maximum Voltage Measurement
20V dc
Absolute Maximum Current Measurement
24mA
Best Accuracy
±0.015 %
Power Source
Battery, Mains
Battery Type
AAA
Dimensions
205 x 98 x 46mm
Weight
472g
Height
45mm
Length
205mm
Maximum Operating Temperature
+55°C
Maximum Source Current
24mA
Width
97mm
Minimum Operating Temperature
-10°C
Minimum Source Current
0mA
Model Number p
CA 1631
Maximum Source Voltage
0 mA, 20 V
Minimum Source Voltage
0V
Distrelec Product Id
30366495
Zemlja podrijetla
China
Detalji o proizvodu
Chauvin Arnoux Calibrators CA1621, CA1623 & CA1631
These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation and measurement. They simulate a signal or generate a quantity with precisely-defined values, for applying upstream of the measurement chain, and measure the signal. The CA1621, CA1623 & CA1631 calibrators are designed to accurately measure, generate or simulate all the low-level signals encountered in industry. Applications include maintenance operations, commissioning, verification, on-line calibration and adjustment and testing of measurement lines.
Informacije o stanju skladišta trenutno nisu dostupne.
Provjerite ponovno kasnije.
P.O.A.
Calibration type
Bez umjeravanja
1
P.O.A.
Calibration type
Bez umjeravanja
1
Tehnička dokumentacija
Tehnički podaci
Proizvođač
Chauvin ArnouxAbsolute Maximum Voltage Measurement
20V dc
Absolute Maximum Current Measurement
24mA
Best Accuracy
±0.015 %
Power Source
Battery, Mains
Battery Type
AAA
Dimensions
205 x 98 x 46mm
Weight
472g
Height
45mm
Length
205mm
Maximum Operating Temperature
+55°C
Maximum Source Current
24mA
Width
97mm
Minimum Operating Temperature
-10°C
Minimum Source Current
0mA
Model Number p
CA 1631
Maximum Source Voltage
0 mA, 20 V
Minimum Source Voltage
0V
Distrelec Product Id
30366495
Zemlja podrijetla
China
Detalji o proizvodu
Chauvin Arnoux Calibrators CA1621, CA1623 & CA1631
These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation and measurement. They simulate a signal or generate a quantity with precisely-defined values, for applying upstream of the measurement chain, and measure the signal. The CA1621, CA1623 & CA1631 calibrators are designed to accurately measure, generate or simulate all the low-level signals encountered in industry. Applications include maintenance operations, commissioning, verification, on-line calibration and adjustment and testing of measurement lines.