Proizvođač
CrouzetMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
DPDT
Voltage Sensing Range
194 → 528 V
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Asymmetry, Phase Failure, Phase Sequence
Time Delay
0.1 → 10s
Series
HWUA
Height
92.6mm
Length
69mm
Minimum Voltage Sensed
194 V
Operating Temperature Range
+50°C
Minimum Operating Temperature
-20°C
Width
35mm
Maximum Operating Temperature
+50°C
Dimensions
69 x 35 x 92.6mm
Maximum Voltage Sensed
528V
Detalji o proizvodu
Multi Function Phase Control Relays 35mm - C-Lynx
The HWUA 3 phase network control relay monitors:- The correct sequence of phases L1, L2, L3,- Total phase failure,- Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay,- Asymmetry rate from 5% to 15% of Under Voltage Relay,- Faults are signalled via LEDs, distinguishing the origin of the fault. If a fault persists for longer than the threshold crossing delay configured by the operator, both output relays open and LED R is extinguished.
Informacije o stanju skladišta trenutno nisu dostupne.
Provjerite ponovno kasnije.
€ 329,52
komadno (bez PDV-a)
€ 411,90
komadno (s PDV-om)
1
€ 329,52
komadno (bez PDV-a)
€ 411,90
komadno (s PDV-om)
1
Kupujte na veliko
količina | jedinična cijena |
---|---|
1 - 4 | € 329,52 |
5 - 9 | € 317,53 |
10 - 24 | € 313,50 |
25 - 49 | € 308,12 |
50+ | € 301,27 |
Tehnička dokumentacija
Tehnički podaci
Proizvođač
CrouzetMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
DPDT
Voltage Sensing Range
194 → 528 V
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Asymmetry, Phase Failure, Phase Sequence
Time Delay
0.1 → 10s
Series
HWUA
Height
92.6mm
Length
69mm
Minimum Voltage Sensed
194 V
Operating Temperature Range
+50°C
Minimum Operating Temperature
-20°C
Width
35mm
Maximum Operating Temperature
+50°C
Dimensions
69 x 35 x 92.6mm
Maximum Voltage Sensed
528V
Detalji o proizvodu
Multi Function Phase Control Relays 35mm - C-Lynx
The HWUA 3 phase network control relay monitors:- The correct sequence of phases L1, L2, L3,- Total phase failure,- Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay,- Asymmetry rate from 5% to 15% of Under Voltage Relay,- Faults are signalled via LEDs, distinguishing the origin of the fault. If a fault persists for longer than the threshold crossing delay configured by the operator, both output relays open and LED R is extinguished.