Crouzet Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 194 → 528 V, DIN Rail

RS kataloški broj:: 262-003robna marka: CrouzetProizvođački broj:: 84873026
brand-logo
Prikaži sve u Monitoring Relays

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Crouzet

Monitoring Application

Phase, Voltage

Electrical Phase

3

Contact Configuration

DPDT

Voltage Sensing Range

194 → 528 V

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Phase Sensitivity

Phase Asymmetry, Phase Failure, Phase Sequence

Time Delay

0.1 → 10s

Series

HWUA

Operating Temperature Range

+50°C

Minimum Operating Temperature

-20°C

Width

35mm

Maximum Operating Temperature

+50°C

Dimensions

69 x 35 x 92.6mm

Maximum Voltage Sensed

528V

Height

92.6mm

Length

69mm

Minimum Voltage Sensed

194 V

Detalji o proizvodu

Multi Function Phase Control Relays 35mm - C-Lynx

The HWUA 3 phase network control relay monitors:- The correct sequence of phases L1, L2, L3,- Total phase failure,- Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay,- Asymmetry rate from 5% to 15% of Under Voltage Relay,- Faults are signalled via LEDs, distinguishing the origin of the fault. If a fault persists for longer than the threshold crossing delay configured by the operator, both output relays open and LED R is extinguished.

Informacije o stanju skladišta trenutno nisu dostupne.

Provjerite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

€ 328,00

komadno (bez PDV-a)

€ 410,00

komadno (s PDV-om)

Crouzet Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 194 → 528 V, DIN Rail

€ 328,00

komadno (bez PDV-a)

€ 410,00

komadno (s PDV-om)

Crouzet Phase, Voltage Monitoring Relay, 3 Phase, DPDT, 194 → 528 V, DIN Rail
Informacije o stanju skladišta trenutno nisu dostupne.

Kupujte na veliko

količinajedinična cijena
1 - 4€ 328,00
5 - 9€ 316,00
10 - 24€ 312,00
25 - 49€ 306,00
50+€ 300,00

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Crouzet

Monitoring Application

Phase, Voltage

Electrical Phase

3

Contact Configuration

DPDT

Voltage Sensing Range

194 → 528 V

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Phase Sensitivity

Phase Asymmetry, Phase Failure, Phase Sequence

Time Delay

0.1 → 10s

Series

HWUA

Operating Temperature Range

+50°C

Minimum Operating Temperature

-20°C

Width

35mm

Maximum Operating Temperature

+50°C

Dimensions

69 x 35 x 92.6mm

Maximum Voltage Sensed

528V

Height

92.6mm

Length

69mm

Minimum Voltage Sensed

194 V

Detalji o proizvodu

Multi Function Phase Control Relays 35mm - C-Lynx

The HWUA 3 phase network control relay monitors:- The correct sequence of phases L1, L2, L3,- Total phase failure,- Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay,- Asymmetry rate from 5% to 15% of Under Voltage Relay,- Faults are signalled via LEDs, distinguishing the origin of the fault. If a fault persists for longer than the threshold crossing delay configured by the operator, both output relays open and LED R is extinguished.