Eaton Series Red Sounder Beacon, 9 → 28 V dc, IP54, IP65, Panel Mount, 101dB at 1 Metre

RS kataloški broj:: 529-3774robna marka: EatonProizvođački broj:: ROLP/RL/R/D
brand-logo
Prikaži sve u Sounder Beacons

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Eaton

Supply Voltage

9 → 28 V dc

Lens Colour

Red

Mounting Style

Panel Mount

Current Type

DC

Light Effect

Flashing

Sounder Type

Electronic

Decibels at 1 Metre

101dB

Series

Eaton Fulleon

Bulb Type

LED

Housing Colour

Red

Maximum Decibel

102dB

IP Rating

IP54, IP65

Number Of Tones

32

Minimum Temperature

-10°C

Housing Material

ABS

Maximum Temperature

+55°C

Special Features

EN54-3

Zemlja podrijetla

United Kingdom

Detalji o proizvodu

Fulleon RoLP Solista LED Sounder Beacon Fire Alarm

Dual alert and alarm functionality are just a few of the leading specifications that allow the Fulleon RoLP Solista range of sounder and beacon combinations to be a popular and reliable solution for users that require an audible and visual alarm device. Predominantly used as a fire alarm, the RoLP sounder beacons provide a convenient, versatile and rugged solutions for industrial and commercial installations. Often, beacons are being used to replace audible alarms, this is because a combined sounder and beacon allows for both audible and visuals through one single installation point. Installing just one device enables users to free up some time and cost.

Warning

This product exceeds the requirements of En54-3 but is not designed to meet EN54-23. Where the Construction Product Directive or Regulation (CPD/CPR) is a country requirement, it cannot be used, legally, for the purpose of alerting room occupants to a Fire Alarm condition. For Countries where CPD/CPR does not apply, this note should be disregarded.

Zamisliti. Stvoriti. Surađivati

PRIDRUŽITE SE BESPLATNO

Bez skrivenih naknada!

design-spark
design-spark
  • Preuzmite i koristite naš softver DesignSpark za svoje PCB i 3D mehaničke dizajne
  • Pregledajte i doprinesite sadržaju internet stranice i foruma
  • Preuzmite 3D modele, sheme i otiske s više od milijun proizvoda
Kliknite ovdje kako biste saznali više

Informacije o stanju skladišta trenutno nisu dostupne.

Provjerite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

€ 129,00

komadno (bez PDV-a)

€ 161,25

komadno (s PDV-om)

Eaton Series Red Sounder Beacon, 9 → 28 V dc, IP54, IP65, Panel Mount, 101dB at 1 Metre

€ 129,00

komadno (bez PDV-a)

€ 161,25

komadno (s PDV-om)

Eaton Series Red Sounder Beacon, 9 → 28 V dc, IP54, IP65, Panel Mount, 101dB at 1 Metre
Informacije o stanju skladišta trenutno nisu dostupne.

Kupujte na veliko

količinajedinična cijena
1 - 9€ 129,00
10+€ 124,00

Zamisliti. Stvoriti. Surađivati

PRIDRUŽITE SE BESPLATNO

Bez skrivenih naknada!

design-spark
design-spark
  • Preuzmite i koristite naš softver DesignSpark za svoje PCB i 3D mehaničke dizajne
  • Pregledajte i doprinesite sadržaju internet stranice i foruma
  • Preuzmite 3D modele, sheme i otiske s više od milijun proizvoda
Kliknite ovdje kako biste saznali više

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Eaton

Supply Voltage

9 → 28 V dc

Lens Colour

Red

Mounting Style

Panel Mount

Current Type

DC

Light Effect

Flashing

Sounder Type

Electronic

Decibels at 1 Metre

101dB

Series

Eaton Fulleon

Bulb Type

LED

Housing Colour

Red

Maximum Decibel

102dB

IP Rating

IP54, IP65

Number Of Tones

32

Minimum Temperature

-10°C

Housing Material

ABS

Maximum Temperature

+55°C

Special Features

EN54-3

Zemlja podrijetla

United Kingdom

Detalji o proizvodu

Fulleon RoLP Solista LED Sounder Beacon Fire Alarm

Dual alert and alarm functionality are just a few of the leading specifications that allow the Fulleon RoLP Solista range of sounder and beacon combinations to be a popular and reliable solution for users that require an audible and visual alarm device. Predominantly used as a fire alarm, the RoLP sounder beacons provide a convenient, versatile and rugged solutions for industrial and commercial installations. Often, beacons are being used to replace audible alarms, this is because a combined sounder and beacon allows for both audible and visuals through one single installation point. Installing just one device enables users to free up some time and cost.

Warning

This product exceeds the requirements of En54-3 but is not designed to meet EN54-23. Where the Construction Product Directive or Regulation (CPD/CPR) is a country requirement, it cannot be used, legally, for the purpose of alerting room occupants to a Fire Alarm condition. For Countries where CPD/CPR does not apply, this note should be disregarded.

Zamisliti. Stvoriti. Surađivati

PRIDRUŽITE SE BESPLATNO

Bez skrivenih naknada!

design-spark
design-spark
  • Preuzmite i koristite naš softver DesignSpark za svoje PCB i 3D mehaničke dizajne
  • Pregledajte i doprinesite sadržaju internet stranice i foruma
  • Preuzmite 3D modele, sheme i otiske s više od milijun proizvoda
Kliknite ovdje kako biste saznali više