Multimeter Type

Digital

Product Type

Multimeter

Display Type

Digital

Resistance Resolution

100mΩ

Model Number

116

Functions Measured

AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance, Temperature

Maximum AC Voltage Measurement

600V ac

Maximum Resistance Measurement

40mΩ

Maximum DC Voltage Measurement

600V dc

Maximum DC Current Measurement

600μA dc

Maximum AC Current Measurement

600μA ac

True RMS

Yes

DC Voltage Accuracy

±0.5 % rdg + 2 Digits

DC Current Accuracy

±1 % rdg + 2 Digits

AC Current Accuracy

±1.5 % rdg + 3 Digits

AC Voltage Accuracy

±1 % rdg + 3 Digits

DC Current Resolution

0.1μA dc

DC Voltage Resolution

0.1 mV dc

AC Voltage Resolution

0.1mV ac

AC Current Resolution

0.1μA ac

Maximum Frequency

1kHz

Minimum Operating Temperature

-10°C

Resistance Measurement Accuracy

±1.5 % rdg + 2 Digits

Battery Life

400h

Maximum Operating Temperature

50°C

Weight

550g

Standards/Approvals

No

Width

84mm

Height

167mm

Length

46mm

Safety Category Level

CAT III

Battery Type

Alkaline

Safety Category Voltage

600V

Calibrated

RSCAL

Zemlja podrijetla

China

Detalji o proizvodu

Fluke 16 True RMS HVAC Digital Multimeter with Built-In Thermometer

The Fluke 16 Digital Multimeter is designed to function like a standard Multimeter and exclusive HVAC modes, unlike other models in the Fluke 10 series, the Fluke 116 comes with a built-in thermometer, allowing engineers to measure temperature and microamp mode for testing flame sensors to quickly troubleshoot problems for HVAC applications. The Fluke 116 measures resistance, continuity, frequency and capacitance. The Fluke 116 Multimeter are independently tested for safe use in CAT III 600 V Environments.

Standards

From Fluke, the 116 is designed for heating, ventilation and air conditioning (HVAC) engineers. The model includes temperature measurement and microamp current ranges to quickly troubleshoot HVAC problems.

Možda će vas zanimati
Fluke Multimeter Kit With RS Calibration
Cijena na upitkomadno (bez PDV-a)
Prikaži sve u Multimetri

Informacije o stanju skladišta trenutno nisu dostupne.

€ 528,33

€ 528,33 komadno (bez PDV-a)

€ 660,41

€ 660,41 komadno (s PDV-om)

Fluke 116 Digital Digital Multimeter True RMS, 600 μA ac, 600 μA dc, 600 V ac, RSCAL Calibrated

Vrsta kalibracije

€ 528,33

€ 528,33 komadno (bez PDV-a)

€ 660,41

€ 660,41 komadno (s PDV-om)

Fluke 116 Digital Digital Multimeter True RMS, 600 μA ac, 600 μA dc, 600 V ac, RSCAL Calibrated

Informacije o stanju skladišta trenutno nisu dostupne.

Vrsta kalibracije

Možda će vas zanimati
Fluke Multimeter Kit With RS Calibration
Cijena na upitkomadno (bez PDV-a)

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Fluke

Multimeter Type

Digital

Product Type

Multimeter

Display Type

Digital

Resistance Resolution

100mΩ

Model Number

116

Functions Measured

AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance, Temperature

Maximum AC Voltage Measurement

600V ac

Maximum Resistance Measurement

40mΩ

Maximum DC Voltage Measurement

600V dc

Maximum DC Current Measurement

600μA dc

Maximum AC Current Measurement

600μA ac

True RMS

Yes

DC Voltage Accuracy

±0.5 % rdg + 2 Digits

DC Current Accuracy

±1 % rdg + 2 Digits

AC Current Accuracy

±1.5 % rdg + 3 Digits

AC Voltage Accuracy

±1 % rdg + 3 Digits

DC Current Resolution

0.1μA dc

DC Voltage Resolution

0.1 mV dc

AC Voltage Resolution

0.1mV ac

AC Current Resolution

0.1μA ac

Maximum Frequency

1kHz

Minimum Operating Temperature

-10°C

Resistance Measurement Accuracy

±1.5 % rdg + 2 Digits

Battery Life

400h

Maximum Operating Temperature

50°C

Weight

550g

Standards/Approvals

No

Width

84mm

Height

167mm

Length

46mm

Safety Category Level

CAT III

Battery Type

Alkaline

Safety Category Voltage

600V

Calibrated

RSCAL

Zemlja podrijetla

China

Detalji o proizvodu

Fluke 16 True RMS HVAC Digital Multimeter with Built-In Thermometer

The Fluke 16 Digital Multimeter is designed to function like a standard Multimeter and exclusive HVAC modes, unlike other models in the Fluke 10 series, the Fluke 116 comes with a built-in thermometer, allowing engineers to measure temperature and microamp mode for testing flame sensors to quickly troubleshoot problems for HVAC applications. The Fluke 116 measures resistance, continuity, frequency and capacitance. The Fluke 116 Multimeter are independently tested for safe use in CAT III 600 V Environments.

Standards

From Fluke, the 116 is designed for heating, ventilation and air conditioning (HVAC) engineers. The model includes temperature measurement and microamp current ranges to quickly troubleshoot HVAC problems.

Možda će vas zanimati
Fluke Multimeter Kit With RS Calibration
Cijena na upitkomadno (bez PDV-a)