Tehnička dokumentacija
Tehnički podaci
Proizvođač
FlukeProduct Type
Loop Calibrator
Model Number
709H
Accuracy
±0.01 %
Resolution
1 μA
Battery Type
Lithium-ion
Battery Life
40h
Power Source
Battery
Minimum Operating Temperature
-10°C
Maximum Operating Temperature
50°C
Width
114 mm
Height
150mm
Length
183mm
Weight
900g
Standards/Approvals
No
Hazardous Area Certification
No
Calibrated
RSCAL
Zemlja podrijetla
United States
Detalji o proizvodu
Fluke 709 Precision Loop Calibrator
The Fluke 709 Precision Loop Calibrator reduces the time it takes to measure or source voltage or current and power up a loop. It is used for installation, calibration and troubleshooting field transmitters, valves and other control system components. Primary functions are source and measure mA signals in the range 0 to 24 mA. The Fluke 709 can measure 0 to 30 V and produce 24Vdc loop power. The 709H includes HART communication functionality and supports a select set of HART universal and common-practice commands. It can be used as a loop calibrator or basic function communicator.
Supplied with
AC72-1 alligator clips (2), TL75 test leads, soft case, 6 AAA batteries (installed), product manual, quick reference guide, safety information
Informacije o stanju skladišta trenutno nisu dostupne.
Cijena na upit
Vrsta kalibracije
RS umjeravanje
1
Cijena na upit
Informacije o stanju skladišta trenutno nisu dostupne.
Vrsta kalibracije
RS umjeravanje
1
Tehnička dokumentacija
Tehnički podaci
Proizvođač
FlukeProduct Type
Loop Calibrator
Model Number
709H
Accuracy
±0.01 %
Resolution
1 μA
Battery Type
Lithium-ion
Battery Life
40h
Power Source
Battery
Minimum Operating Temperature
-10°C
Maximum Operating Temperature
50°C
Width
114 mm
Height
150mm
Length
183mm
Weight
900g
Standards/Approvals
No
Hazardous Area Certification
No
Calibrated
RSCAL
Zemlja podrijetla
United States
Detalji o proizvodu
Fluke 709 Precision Loop Calibrator
The Fluke 709 Precision Loop Calibrator reduces the time it takes to measure or source voltage or current and power up a loop. It is used for installation, calibration and troubleshooting field transmitters, valves and other control system components. Primary functions are source and measure mA signals in the range 0 to 24 mA. The Fluke 709 can measure 0 to 30 V and produce 24Vdc loop power. The 709H includes HART communication functionality and supports a select set of HART universal and common-practice commands. It can be used as a loop calibrator or basic function communicator.
Supplied with
AC72-1 alligator clips (2), TL75 test leads, soft case, 6 AAA batteries (installed), product manual, quick reference guide, safety information
