MADE TRIPHASOR Cable Tracer, Maximum Safe Working Voltage 230 V ac, 240 V ac

RS kataloški broj:: 122-5894robna marka: MADEProizvođački broj:: TRIPHASOR
brand-logo

Tehnička dokumentacija

Tehnički podaci

Proizvođač

MADE

Display Type

LED

Meter Type

Cable Tracer

Battery Type

Ni-Cd

Power Source

Battery, Mains

Includes

Charger, Connection Cable, Crocodile Clip x 4, Current Clamp, MADE Flex Rogowski Coil x 3, One Pack of Replacement Fuses, Probe x 2, Receiver, Transmitter

Maximum Frequency

60Hz

Maximum Safe Working Voltage

230 V ac, 240 V ac

Minimum Frequency

50 Hz

Minimum Safe Working Voltage

100 V ac, 115 V ac

Model Number p

TRIPHASOR

Zemlja podrijetla

France

Detalji o proizvodu

MADE TRIPHASOR Cable Tracer

TRIPHASOR is an instrument for optimising the operation of electrical distribution networks. It measures the electric grid characteristics in real time and enables the identification of each phase on a phased network. TRIPHASOR is used on live low tension networks, under load.

TRIPHASOR consists of a transmitter and a receiver, both can be used on a live LV electric network. The transmitter must be connected in a substation using the voltage LV cords and the current clamp. The receiver allows phase identifying wherever it is connected between phase and neutral, anywhere on the live network.

Informacije o stanju skladišta trenutno nisu dostupne.

Provjerite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

P.O.A.

MADE TRIPHASOR Cable Tracer, Maximum Safe Working Voltage 230 V ac, 240 V ac

P.O.A.

MADE TRIPHASOR Cable Tracer, Maximum Safe Working Voltage 230 V ac, 240 V ac
Informacije o stanju skladišta trenutno nisu dostupne.

Tehnička dokumentacija

Tehnički podaci

Proizvođač

MADE

Display Type

LED

Meter Type

Cable Tracer

Battery Type

Ni-Cd

Power Source

Battery, Mains

Includes

Charger, Connection Cable, Crocodile Clip x 4, Current Clamp, MADE Flex Rogowski Coil x 3, One Pack of Replacement Fuses, Probe x 2, Receiver, Transmitter

Maximum Frequency

60Hz

Maximum Safe Working Voltage

230 V ac, 240 V ac

Minimum Frequency

50 Hz

Minimum Safe Working Voltage

100 V ac, 115 V ac

Model Number p

TRIPHASOR

Zemlja podrijetla

France

Detalji o proizvodu

MADE TRIPHASOR Cable Tracer

TRIPHASOR is an instrument for optimising the operation of electrical distribution networks. It measures the electric grid characteristics in real time and enables the identification of each phase on a phased network. TRIPHASOR is used on live low tension networks, under load.

TRIPHASOR consists of a transmitter and a receiver, both can be used on a live LV electric network. The transmitter must be connected in a substation using the voltage LV cords and the current clamp. The receiver allows phase identifying wherever it is connected between phase and neutral, anywhere on the live network.