Megger DET4TCR2 Earth Tester, 200kΩ CAT IV 100 V

RS kataloški broj:: 489-670robna marka: MeggerProizvođački broj:: 1000-366
brand-logo
Prikaži sve u Earth Testers

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Megger

Absolute Maximum Resistance Measurement

200kΩ

Best Accuracy

±2% + 3 Digits

Measurement Type

4 Terminal Earth Resistance, Soil Resistance

Display Type

LCD

Safety Category

CAT IV 100 V

Battery Life

3 h

Battery Type

AA

Power Source

Battery

Dimensions

203 x 148 x 78mm

Weight

1kg

Height

148mm

Includes

Calibration Certificate, Case, External AC/DC Adapter, Field Calibrator, ICLAMP & VCLAMP, Terminal Adapter, Test Lead

Length

203mm

Maximum Operating Temperature

+55°C

Width

78mm

Minimum Operating Temperature

-15°C

Model Number p

DET4TCR2

Safety Category Level

CAT IV

Zemlja podrijetla

United Kingdom

Detalji o proizvodu

DET4TCR/2 4 Pole Rechargeable Earth Tester Kit

4 pole earth tester with rechargeable batteries for measuring soil resistivity and resistance of earth rods and associated installations.,The ICLAMP selective clamp allows the DET4TCR/2 to perform testing of an earth rod without the need for disconnection from the system.,The VCLAMP when used in conjunction with ICLAMP allows stakeless measurements to be made in situations where driving auxiliary stakes is not practical

Supplied with

ICLAMP, VCLAMP, 4 earth test stakes, 4 connection leads, field calibration check for instrument and CLAMPS, 8 x AA NiMH rechargeable batteries, hard carry case, mains charger, quick start guides, user guide on CD

Standards

EN61010-1 CAT IV 100V

Informacije o stanju skladišta trenutno nisu dostupne.

Provjerite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

P.O.A.

Megger DET4TCR2 Earth Tester, 200kΩ CAT IV 100 V

P.O.A.

Megger DET4TCR2 Earth Tester, 200kΩ CAT IV 100 V
Informacije o stanju skladišta trenutno nisu dostupne.

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Megger

Absolute Maximum Resistance Measurement

200kΩ

Best Accuracy

±2% + 3 Digits

Measurement Type

4 Terminal Earth Resistance, Soil Resistance

Display Type

LCD

Safety Category

CAT IV 100 V

Battery Life

3 h

Battery Type

AA

Power Source

Battery

Dimensions

203 x 148 x 78mm

Weight

1kg

Height

148mm

Includes

Calibration Certificate, Case, External AC/DC Adapter, Field Calibrator, ICLAMP & VCLAMP, Terminal Adapter, Test Lead

Length

203mm

Maximum Operating Temperature

+55°C

Width

78mm

Minimum Operating Temperature

-15°C

Model Number p

DET4TCR2

Safety Category Level

CAT IV

Zemlja podrijetla

United Kingdom

Detalji o proizvodu

DET4TCR/2 4 Pole Rechargeable Earth Tester Kit

4 pole earth tester with rechargeable batteries for measuring soil resistivity and resistance of earth rods and associated installations.,The ICLAMP selective clamp allows the DET4TCR/2 to perform testing of an earth rod without the need for disconnection from the system.,The VCLAMP when used in conjunction with ICLAMP allows stakeless measurements to be made in situations where driving auxiliary stakes is not practical

Supplied with

ICLAMP, VCLAMP, 4 earth test stakes, 4 connection leads, field calibration check for instrument and CLAMPS, 8 x AA NiMH rechargeable batteries, hard carry case, mains charger, quick start guides, user guide on CD

Standards

EN61010-1 CAT IV 100V