Tehnička dokumentacija
Tehnički podaci
Proizvođač
ParkerProduct Type
Pneumatic Timer
Hazardous Area Certification
LCIE 866115X
Minimum Operating Pressure
3bar
Mount Type
DIN Rail
Maximum Operating Pressure
8 bar
Minimum Operating Temperature
-15°C
Maximum Operating Temperature
60°C
Standards/Approvals
NFC 23519, NFC 23514, EN 50019, EN 50014, EExe II T4code
Detalji o proizvodu
Timer Module
A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.
Logic Systems
Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.
Informacije o stanju skladišta trenutno nisu dostupne.
€ 400,18
€ 400,18 komadno (bez PDV-a)
€ 500,22
€ 500,22 komadno (s PDV-om)
1
€ 400,18
€ 400,18 komadno (bez PDV-a)
€ 500,22
€ 500,22 komadno (s PDV-om)
Informacije o stanju skladišta trenutno nisu dostupne.
1
| količina | jedinična cijena |
|---|---|
| 1 - 4 | € 400,18 |
| 5+ | € 389,70 |
Tehnička dokumentacija
Tehnički podaci
Proizvođač
ParkerProduct Type
Pneumatic Timer
Hazardous Area Certification
LCIE 866115X
Minimum Operating Pressure
3bar
Mount Type
DIN Rail
Maximum Operating Pressure
8 bar
Minimum Operating Temperature
-15°C
Maximum Operating Temperature
60°C
Standards/Approvals
NFC 23519, NFC 23514, EN 50019, EN 50014, EExe II T4code
Detalji o proizvodu
Timer Module
A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.
Logic Systems
Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.