Phoenix Contact, LIT 1X2-24 Surge Protector 24 V dc Maximum Voltage Rating 20kA Maximum Surge Current Surge Arrester

RS kataloški broj:: 802-6678robna marka: Phoenix ContactProizvođački broj:: 2804610
brand-logo
Prikaži sve u Surge Suppressor Units

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Phoenix Contact

Suppressor Type

Surge Arrester Protection Module

Maximum Voltage Rating

24 V dc

Mounting Type

DIN Rail

Maximum Surge Current

20kA

Series

LIT 1X2-24

Length

93.1mm

Depth

6.2mm

Height

102.5mm

Dimensions

93.1 x 6.2 x 102.5mm

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+80°C

Zemlja podrijetla

Germany

Detalji o proizvodu

LINETRAB LIT Surge Protection

Phoenix Contact LineTrab LIT range of DIN rail mounted surge protection equipment for measurement and control technology. The LineTrab range has a design width of just 6.2 mm yet it is able to offer protection for up to four wires.

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Zamisliti. Stvoriti. Surađivati

PRIDRUŽITE SE BESPLATNO

Bez skrivenih naknada!

design-spark
design-spark
  • Preuzmite i koristite naš softver DesignSpark za svoje PCB i 3D mehaničke dizajne
  • Pregledajte i doprinesite sadržaju internet stranice i foruma
  • Preuzmite 3D modele, sheme i otiske s više od milijun proizvoda
Kliknite ovdje kako biste saznali više

Informacije o stanju skladišta trenutno nisu dostupne.

Provjerite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

€ 161,00

komadno (bez PDV-a)

€ 201,25

komadno (s PDV-om)

Phoenix Contact, LIT 1X2-24 Surge Protector 24 V dc Maximum Voltage Rating 20kA Maximum Surge Current Surge Arrester

€ 161,00

komadno (bez PDV-a)

€ 201,25

komadno (s PDV-om)

Phoenix Contact, LIT 1X2-24 Surge Protector 24 V dc Maximum Voltage Rating 20kA Maximum Surge Current Surge Arrester
Informacije o stanju skladišta trenutno nisu dostupne.

Kupujte na veliko

količinajedinična cijena
1 - 4€ 161,00
5 - 9€ 156,00
10 - 24€ 154,00
25+€ 147,00

Zamisliti. Stvoriti. Surađivati

PRIDRUŽITE SE BESPLATNO

Bez skrivenih naknada!

design-spark
design-spark
  • Preuzmite i koristite naš softver DesignSpark za svoje PCB i 3D mehaničke dizajne
  • Pregledajte i doprinesite sadržaju internet stranice i foruma
  • Preuzmite 3D modele, sheme i otiske s više od milijun proizvoda
Kliknite ovdje kako biste saznali više

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Phoenix Contact

Suppressor Type

Surge Arrester Protection Module

Maximum Voltage Rating

24 V dc

Mounting Type

DIN Rail

Maximum Surge Current

20kA

Series

LIT 1X2-24

Length

93.1mm

Depth

6.2mm

Height

102.5mm

Dimensions

93.1 x 6.2 x 102.5mm

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+80°C

Zemlja podrijetla

Germany

Detalji o proizvodu

LINETRAB LIT Surge Protection

Phoenix Contact LineTrab LIT range of DIN rail mounted surge protection equipment for measurement and control technology. The LineTrab range has a design width of just 6.2 mm yet it is able to offer protection for up to four wires.

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Zamisliti. Stvoriti. Surađivati

PRIDRUŽITE SE BESPLATNO

Bez skrivenih naknada!

design-spark
design-spark
  • Preuzmite i koristite naš softver DesignSpark za svoje PCB i 3D mehaničke dizajne
  • Pregledajte i doprinesite sadržaju internet stranice i foruma
  • Preuzmite 3D modele, sheme i otiske s više od milijun proizvoda
Kliknite ovdje kako biste saznali više