Tehnička dokumentacija
Tehnički podaci
Proizvođač
PR ElectronicsProduct Type
Signal Conditioner
Input Signal Type
Current
Output Signal Type
Relay, Current
Supply Voltage
19.2/31.2 V dc
Hazardous Area Certification
Zone 2, ATEX, UL, DNV GL, EU RO marine, Zone, IECEx, FM, EAC
Mount Type
DIN Rail
Terminal Type
Screw
Maximum Operating Temperature
60°C
Minimum Operating Temperature
-20°C
IP Rating
IP20
Standards/Approvals
EAC, NE 43, Zone 2-DIV 2, ATEX, NE 21, UL 61010 / 508, IECEX, DNV-GL / EU-RO marine, Zone 2, FM
Series
9
Zemlja podrijetla
Denmark
Detalji o proizvodu
9106B Type - Ex HART Transparent Repeater
PR Electronics 9106B is a HART transparent isolated repeater barrier for intrinsic safety applications. The 9106B signal conditioning repeater supplies 2-wire SMART transmitters and can also be used for 2-wire SMART current sources. HART & BRAIN protocols are supported and are transferred bi-directionally. Used anywhere intrinsically safe levels of energy need to be sent to devices located in a flammable atmosphere. The 9106B has been designed, developed and certified for use in SIL 3 applications according to the requirements of IEC 61508.
PR Electronics - Ex Interfaces
Informacije o stanju skladišta trenutno nisu dostupne.
Cijena na upit
1
Cijena na upit
Informacije o stanju skladišta trenutno nisu dostupne.
1
Tehnička dokumentacija
Tehnički podaci
Proizvođač
PR ElectronicsProduct Type
Signal Conditioner
Input Signal Type
Current
Output Signal Type
Relay, Current
Supply Voltage
19.2/31.2 V dc
Hazardous Area Certification
Zone 2, ATEX, UL, DNV GL, EU RO marine, Zone, IECEx, FM, EAC
Mount Type
DIN Rail
Terminal Type
Screw
Maximum Operating Temperature
60°C
Minimum Operating Temperature
-20°C
IP Rating
IP20
Standards/Approvals
EAC, NE 43, Zone 2-DIV 2, ATEX, NE 21, UL 61010 / 508, IECEX, DNV-GL / EU-RO marine, Zone 2, FM
Series
9
Zemlja podrijetla
Denmark
Detalji o proizvodu
9106B Type - Ex HART Transparent Repeater
PR Electronics 9106B is a HART transparent isolated repeater barrier for intrinsic safety applications. The 9106B signal conditioning repeater supplies 2-wire SMART transmitters and can also be used for 2-wire SMART current sources. HART & BRAIN protocols are supported and are transferred bi-directionally. Used anywhere intrinsically safe levels of energy need to be sent to devices located in a flammable atmosphere. The 9106B has been designed, developed and certified for use in SIL 3 applications according to the requirements of IEC 61508.