RS PRO MINI Series Signal Conditioner, Current/Voltage Input, Current/Voltage Output, 10V dc, 30 V dc Supply

RS kataloški broj:: 218-4469robna marka: RS PRO
brand-logo
Prikaži sve u Signal Conditioners

Tehnička dokumentacija

Tehnički podaci

Proizvođač

RS Pro

Product Type

Signal Conditioner

Input Signal Type

Current/Voltage

Output Signal Type

Current/Voltage

Input Range

0 → 20 mA, -250 → +250 V dc

Output Range

0 → 10 mA, 0 → 10 V dc

Supply Voltage

10, 30V dc

Hazardous Area Certification

No

Mount Type

DIN Rail

Minimum Operating Temperature

0°C

Terminal Type

Screw

Maximum Operating Temperature

50°C

Signal Conditioner Type

Signal Isolator

Standards/Approvals

No

Series

MINI

Number of Channels

1

Zemlja podrijetla

United Kingdom

Detalji o proizvodu

24Vdc Trip Amplifiers, Signal Isolator/Converters

Symmetric DIN rail mounting units with finger protected terminals designed for use in process control and instrumentation applications. Single or dual level trip amplifiers from a single Input.Each trip can be arranged so that the alarm condition can be above (high trip) or below (low trip) the set point, and that the relay can be either normally energised to de-energise in the alarm condition (fail-safe), or normally de-energised to energise in the alarm condition (non fail-safe).,signal Isolators/converter; this unit conditions the signal before sending it through an opto-isolated hybrid circuit. Input and output stages are power from separate secondaries of the dc/dc inverter to provide 3 port isolation

Prikaži sve u Signal Conditioners

Informacije o stanju skladišta trenutno nisu dostupne.

€ 300,33

€ 300,33 komadno (bez PDV-a)

€ 375,41

€ 375,41 komadno (s PDV-om)

RS PRO MINI Series Signal Conditioner, Current/Voltage Input, Current/Voltage Output, 10V dc, 30 V dc Supply

€ 300,33

€ 300,33 komadno (bez PDV-a)

€ 375,41

€ 375,41 komadno (s PDV-om)

RS PRO MINI Series Signal Conditioner, Current/Voltage Input, Current/Voltage Output, 10V dc, 30 V dc Supply

Informacije o stanju skladišta trenutno nisu dostupne.

Tehnička dokumentacija

Tehnički podaci

Proizvođač

RS Pro

Product Type

Signal Conditioner

Input Signal Type

Current/Voltage

Output Signal Type

Current/Voltage

Input Range

0 → 20 mA, -250 → +250 V dc

Output Range

0 → 10 mA, 0 → 10 V dc

Supply Voltage

10, 30V dc

Hazardous Area Certification

No

Mount Type

DIN Rail

Minimum Operating Temperature

0°C

Terminal Type

Screw

Maximum Operating Temperature

50°C

Signal Conditioner Type

Signal Isolator

Standards/Approvals

No

Series

MINI

Number of Channels

1

Zemlja podrijetla

United Kingdom

Detalji o proizvodu

24Vdc Trip Amplifiers, Signal Isolator/Converters

Symmetric DIN rail mounting units with finger protected terminals designed for use in process control and instrumentation applications. Single or dual level trip amplifiers from a single Input.Each trip can be arranged so that the alarm condition can be above (high trip) or below (low trip) the set point, and that the relay can be either normally energised to de-energise in the alarm condition (fail-safe), or normally de-energised to energise in the alarm condition (non fail-safe).,signal Isolators/converter; this unit conditions the signal before sending it through an opto-isolated hybrid circuit. Input and output stages are power from separate secondaries of the dc/dc inverter to provide 3 port isolation