Schneider Electric Choke for Use with Altivar 61 Series, 155mm Length, 3-Phase, 200 → 690 V

RS kataloški broj:: 656-0722robna marka: Schneider ElectricProizvođački broj:: VW3A4554
brand-logo
Prikaži sve u Motor Accessories

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Schneider Electric

Accessory Type

Choke

For Use With

Altivar 61 Series

Voltage Range

200 → 690 V

Electrical Phase

3

Length

155mm

Depth

135mm

Dimensions

155 x 170 x 135 mm

Zemlja podrijetla

France

Detalji o proizvodu

Altivar AC Line Choke

A line choke can be used to provide improved protection against overvoltages on the line supply and to reduce the current harmonics produced by the drive. The recommended chokes can be used to limit the line current. They have been developed in line with standard EN 50178 (VDE 0160 level 1 high energy overvoltages on the line supply). The inductance values are defined for a voltage drop between phases of between 3% and 5% of the nominal line voltage. Values higher than this will cause loss of torque. These chokes should be installed upstream of the drive.

Informacije o stanju skladišta trenutno nisu dostupne.

Provjerite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

€ 535,74

komadno (bez PDV-a)

€ 669,68

komadno (s PDV-om)

Schneider Electric Choke for Use with Altivar 61 Series, 155mm Length, 3-Phase, 200 → 690 V

€ 535,74

komadno (bez PDV-a)

€ 669,68

komadno (s PDV-om)

Schneider Electric Choke for Use with Altivar 61 Series, 155mm Length, 3-Phase, 200 → 690 V
Informacije o stanju skladišta trenutno nisu dostupne.

Kupujte na veliko

količinajedinična cijena
1 - 4€ 535,74
5+€ 528,26

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Schneider Electric

Accessory Type

Choke

For Use With

Altivar 61 Series

Voltage Range

200 → 690 V

Electrical Phase

3

Length

155mm

Depth

135mm

Dimensions

155 x 170 x 135 mm

Zemlja podrijetla

France

Detalji o proizvodu

Altivar AC Line Choke

A line choke can be used to provide improved protection against overvoltages on the line supply and to reduce the current harmonics produced by the drive. The recommended chokes can be used to limit the line current. They have been developed in line with standard EN 50178 (VDE 0160 level 1 high energy overvoltages on the line supply). The inductance values are defined for a voltage drop between phases of between 3% and 5% of the nominal line voltage. Values higher than this will cause loss of torque. These chokes should be installed upstream of the drive.