Tehnička dokumentacija
Tehnički podaci
Brand
BulginFuse Holder Type
Panel Mount
Fuse Size
5 x 20mm
Current Rating
6.3A
Voltage Rating
250V ac
Number of Poles
1P
Includes Indicator
No
Cap Style
Slotted
Series
FX
Compatible Fuse Diameter
5mm
International Protection Rating
IP66
Protection Category
PC1
Contact Material
Silver Plated Brass
Terminal Type
Solder
Compatible Fuse Length
20mm
Zemlja podrijetla
Tunisia
Detalji o proizvodu
Screw Cap, Panel & Barrier Sealed
Panel Mounting
CATEGORIES OF PROTECTION AGAINST ELECTRIC SHOCK,PC1: No integral protection against electric shock. If required, designers must provide additional protection against electric shock on equipment.,PC2: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 standard test finger, when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.,PC3: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 1mm diameter rigid test wire when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.
Informacije o stanju skladišta trenutno nisu dostupne.
Proverite ponovno kasnije.
RSD 1.892
Each (bez PDV-a)
RSD 2.270
Each (s PDV-om)
1
RSD 1.892
Each (bez PDV-a)
RSD 2.270
Each (s PDV-om)
1
Kupujte na veliko
količina | Jedinična cena |
---|---|
1 - 9 | RSD 1.892 |
10 - 24 | RSD 1.779 |
25 - 49 | RSD 1.636 |
50+ | RSD 1.561 |
Tehnička dokumentacija
Tehnički podaci
Brand
BulginFuse Holder Type
Panel Mount
Fuse Size
5 x 20mm
Current Rating
6.3A
Voltage Rating
250V ac
Number of Poles
1P
Includes Indicator
No
Cap Style
Slotted
Series
FX
Compatible Fuse Diameter
5mm
International Protection Rating
IP66
Protection Category
PC1
Contact Material
Silver Plated Brass
Terminal Type
Solder
Compatible Fuse Length
20mm
Zemlja podrijetla
Tunisia
Detalji o proizvodu
Screw Cap, Panel & Barrier Sealed
Panel Mounting
CATEGORIES OF PROTECTION AGAINST ELECTRIC SHOCK,PC1: No integral protection against electric shock. If required, designers must provide additional protection against electric shock on equipment.,PC2: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 standard test finger, when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.,PC3: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 1mm diameter rigid test wire when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.