Chauvin Arnoux F402 Clamp Meter, Max Current 1000A ac CAT III 1500V

RS kataloški broj:: 766-0602brend: Chauvin ArnouxProizvođački broj:: P01120942
brand-logo
Prikaži sve u Clamp Meters

Tehnička dokumentacija

Tehnički podaci

Absolute Maximum AC Current Measurement

1000A ac

Absolute Maximum AC Voltage Measurement

1200V ac

Absolute Maximum DC Voltage Measurement

1700V dc

Absolute Maximum Resistance Measurement

99.99kΩ

Model Number

F402

AC Current Measurement Resolution

10mA

Clamp Meter Type

AC Current Clamp Meter

Best AC Current Accuracy

±(1% rdg + 3dgts)

Best AC Voltage Accuracy

±(1% rdg + 3dgts)

Best DC Voltage Accuracy

±(1% rdg + 3dgts)

Functions Measured

AC Current, AC Voltage, Continuity, DC Voltage, Diode, Frequency, In-Rush Current, Resistance, Temperature

True RMS

Yes

Jaw Capacity Busbars

48mm

Absolute Maximum Temperature Measurement

+1000°C

Safety Category

CAT III 1500 V, CAT IV 1000V

Best Resistance Measurement Accuracy

±1 % + 5 digits

Display Type

Backlit LCD

Maximum Operating Temperature

+55°C

Power Source

Battery

Non-Contact Voltage Detector

No

Width

92mm

Length

272mm

Resistance Measurement Resolution

100mΩ

Dimensions

92 x 272 x 41mm

DC Voltage Measurement Resolution

10mV

Best Temperature Measurement Accuracy

±1% +3°C

Minimum Operating Temperature

-20°C

Height

41mm

AC Voltage Measurement Resolution

10mV

AC Current Measurement Range

0.25 to 1000 A AC

AC Voltage Measurement Range

0.15 to 1200 V AC

Maximum Conductor Size

48mm

Battery Life

>350 h

Safety Category Level

CAT III, CAT IV

Temperature Measurement Resolution

0.1°C

Safety Category Voltage

CAT III 1500 V, CAT IV 1000V

Battery Type

LR6

Weight

600g

Zemlja podrijetla

China

Detalji o proizvodu

F401 TRMS Clamp Multimeter

Informacije o stanju skladišta trenutno nisu dostupne.

Proverite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

RSD 72.894

Each (bez PDV-a)

RSD 87.473

Each (s PDV-om)

Chauvin Arnoux F402 Clamp Meter, Max Current 1000A ac CAT III 1500V

Calibration type

RSD 72.894

Each (bez PDV-a)

RSD 87.473

Each (s PDV-om)

Chauvin Arnoux F402 Clamp Meter, Max Current 1000A ac CAT III 1500V
Informacije o stanju skladišta trenutno nisu dostupne.

Calibration type

Tehnička dokumentacija

Tehnički podaci

Absolute Maximum AC Current Measurement

1000A ac

Absolute Maximum AC Voltage Measurement

1200V ac

Absolute Maximum DC Voltage Measurement

1700V dc

Absolute Maximum Resistance Measurement

99.99kΩ

Model Number

F402

AC Current Measurement Resolution

10mA

Clamp Meter Type

AC Current Clamp Meter

Best AC Current Accuracy

±(1% rdg + 3dgts)

Best AC Voltage Accuracy

±(1% rdg + 3dgts)

Best DC Voltage Accuracy

±(1% rdg + 3dgts)

Functions Measured

AC Current, AC Voltage, Continuity, DC Voltage, Diode, Frequency, In-Rush Current, Resistance, Temperature

True RMS

Yes

Jaw Capacity Busbars

48mm

Absolute Maximum Temperature Measurement

+1000°C

Safety Category

CAT III 1500 V, CAT IV 1000V

Best Resistance Measurement Accuracy

±1 % + 5 digits

Display Type

Backlit LCD

Maximum Operating Temperature

+55°C

Power Source

Battery

Non-Contact Voltage Detector

No

Width

92mm

Length

272mm

Resistance Measurement Resolution

100mΩ

Dimensions

92 x 272 x 41mm

DC Voltage Measurement Resolution

10mV

Best Temperature Measurement Accuracy

±1% +3°C

Minimum Operating Temperature

-20°C

Height

41mm

AC Voltage Measurement Resolution

10mV

AC Current Measurement Range

0.25 to 1000 A AC

AC Voltage Measurement Range

0.15 to 1200 V AC

Maximum Conductor Size

48mm

Battery Life

>350 h

Safety Category Level

CAT III, CAT IV

Temperature Measurement Resolution

0.1°C

Safety Category Voltage

CAT III 1500 V, CAT IV 1000V

Battery Type

LR6

Weight

600g

Zemlja podrijetla

China

Detalji o proizvodu

F401 TRMS Clamp Multimeter