Schneider Electric Single/Dual-Channel Light Beam/Curtain Safety Relay, 115V ac, 7 Safety Contacts

RS kataloški broj:: 447-4512brend: Schneider ElectricProizvođački broj:: XPSAR351144
brand-logo
Prikaži sve u Safety Relays

Tehnička dokumentacija

Tehnički podaci

Material Properties

Robust Design

Model Number p

159624

American Wire Gauge

16 → 28AWG

Shock Absorber Type

Mounting Block

10 Digit ISBN

0852967934

Model Number p

8091678

Imperial Size

3/4 in, 13/16 in

Height

41mm

Fan Size

226 x 226mm

Thread Size

1/4 in NPT

Frequency Range

1710 → 2710 MHz, 2500 → 2700 MHz, 689 → 960 MHz

Series

216571

Accessory Type

Base plate for mounting

Standards Met

RoHS Compliant

Length

99mm

Depth

114mm

Series

140MP-A

Detalji o proizvodu

Bellows

This range of bellows operates most herga airswitches. The economical rugged bellow is designed for panel mounting.

Actuators, Switch Elements, Tubing & Accessories

The air operated switch system offers enhanced safety in hazardous areas by allowing remote operation of electrical circuits.
The actuator is a bellows which, when compressed moves air down the air tubing to the switch element. This compressed air then expands a bellows in the switch, which operates the electrical contacts.
When used in wet environments or where electrical switching would be dangerous due to arcing, the switch and all electrical wiring can be located outside the hazardous area giving the operator total electrical isolation for the equipment.
Such applications include: Battery charging rooms, laboratories, garages, or wherever explosive gases, vapours or powders may exist.

When assembled the air switch and actuator form a sealed system, therefore temperature variation will cause pressure changes, which can in extreme cases affect the performance of the switch. To prevent this the total volume of the system must be kept below a critical value for a given temperature range and, to this end, a maximum length of air tubing (and hence volume) can be given for any combination of switch and actuator.
The additional data tables give these lengths in metres; for moderate and extreme temperatures.

Informacije o stanju skladišta trenutno nisu dostupne.

Proverite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

P.O.A.

Schneider Electric Single/Dual-Channel Light Beam/Curtain Safety Relay, 115V ac, 7 Safety Contacts

P.O.A.

Schneider Electric Single/Dual-Channel Light Beam/Curtain Safety Relay, 115V ac, 7 Safety Contacts
Informacije o stanju skladišta trenutno nisu dostupne.

Tehnička dokumentacija

Tehnički podaci

Material Properties

Robust Design

Model Number p

159624

American Wire Gauge

16 → 28AWG

Shock Absorber Type

Mounting Block

10 Digit ISBN

0852967934

Model Number p

8091678

Imperial Size

3/4 in, 13/16 in

Height

41mm

Fan Size

226 x 226mm

Thread Size

1/4 in NPT

Frequency Range

1710 → 2710 MHz, 2500 → 2700 MHz, 689 → 960 MHz

Series

216571

Accessory Type

Base plate for mounting

Standards Met

RoHS Compliant

Length

99mm

Depth

114mm

Series

140MP-A

Detalji o proizvodu

Bellows

This range of bellows operates most herga airswitches. The economical rugged bellow is designed for panel mounting.

Actuators, Switch Elements, Tubing & Accessories

The air operated switch system offers enhanced safety in hazardous areas by allowing remote operation of electrical circuits.
The actuator is a bellows which, when compressed moves air down the air tubing to the switch element. This compressed air then expands a bellows in the switch, which operates the electrical contacts.
When used in wet environments or where electrical switching would be dangerous due to arcing, the switch and all electrical wiring can be located outside the hazardous area giving the operator total electrical isolation for the equipment.
Such applications include: Battery charging rooms, laboratories, garages, or wherever explosive gases, vapours or powders may exist.

When assembled the air switch and actuator form a sealed system, therefore temperature variation will cause pressure changes, which can in extreme cases affect the performance of the switch. To prevent this the total volume of the system must be kept below a critical value for a given temperature range and, to this end, a maximum length of air tubing (and hence volume) can be given for any combination of switch and actuator.
The additional data tables give these lengths in metres; for moderate and extreme temperatures.