Tehnička dokumentacija
Tehnički podaci
Brand
WielandSupply Voltage
24V dc
Number of Channels
2
Safety Contacts
3
Function
Safety Monitoring
Reset Method
Manual
Range
safeRELAY
Safety Category ISO 13849-1
4
PL ISO 13849-1
e
SIL IEC 61508
3
Terminal Type
Screw
Series
SNO 4083
Width
22.5mm
Depth
114mm
Performance Level
e
Length
96.5mm
Zemlja podrijetla
Germany
Detalji o proizvodu
Wieland SNO 4083KM Safety Relay
SNO 4083KM Safety Relay Function - after the supply voltage is applied to terminals A1/A2 and the safety inputs are closed, the enabling current paths (NO contacts) are closed and the signal current path (NC contact) is opened automatically or by pressing the reset button (manual monitored start). When the safety inputs are opened/de-energized the enabling current paths (NO contacts) are opened immediately and the signal current path (NC contact) is closed.
The SNO 4083KM safety relay requires fewer connection cables, irrespective of whether operation with or without cross monitoring is desired. The two channel control of the SNO 4083KM is carried out by either an NC/NC or an NC/NO combination of the safety sensor. In the case of two channel control of the device, a synchronous time is automatically monitored between the two channels. The SafeStart function is used with a manual start, the reset input is automatically monitored for a rising and falling signal edge. The Monoflop function is integrated into the safety relay and prevents device interlocking under all circumstances. Simple diagnosis is possible thanks to an intelligent display system that shows the user the different operating modes of the safety relay in its different applications.
Informacije o stanju skladišta trenutno nisu dostupne.
Proverite ponovno kasnije.
RSD 60.867
Each (bez PDV-a)
RSD 73.040
Each (s PDV-om)
1
RSD 60.867
Each (bez PDV-a)
RSD 73.040
Each (s PDV-om)
1
Tehnička dokumentacija
Tehnički podaci
Brand
WielandSupply Voltage
24V dc
Number of Channels
2
Safety Contacts
3
Function
Safety Monitoring
Reset Method
Manual
Range
safeRELAY
Safety Category ISO 13849-1
4
PL ISO 13849-1
e
SIL IEC 61508
3
Terminal Type
Screw
Series
SNO 4083
Width
22.5mm
Depth
114mm
Performance Level
e
Length
96.5mm
Zemlja podrijetla
Germany
Detalji o proizvodu
Wieland SNO 4083KM Safety Relay
SNO 4083KM Safety Relay Function - after the supply voltage is applied to terminals A1/A2 and the safety inputs are closed, the enabling current paths (NO contacts) are closed and the signal current path (NC contact) is opened automatically or by pressing the reset button (manual monitored start). When the safety inputs are opened/de-energized the enabling current paths (NO contacts) are opened immediately and the signal current path (NC contact) is closed.
The SNO 4083KM safety relay requires fewer connection cables, irrespective of whether operation with or without cross monitoring is desired. The two channel control of the SNO 4083KM is carried out by either an NC/NC or an NC/NO combination of the safety sensor. In the case of two channel control of the device, a synchronous time is automatically monitored between the two channels. The SafeStart function is used with a manual start, the reset input is automatically monitored for a rising and falling signal edge. The Monoflop function is integrated into the safety relay and prevents device interlocking under all circumstances. Simple diagnosis is possible thanks to an intelligent display system that shows the user the different operating modes of the safety relay in its different applications.