Dehn, DG Modular Surge Protector 275 V Maximum Voltage Rating 40kA Maximum Surge Current Type 2 Arrester

RS kataloški broj:: 847-0977brend: DehnProizvođački broj:: DG M TNC 275
brand-logo
Prikaži sve u Surge Suppressor Units

Tehnička dokumentacija

Tehnički podaci

Brand

Dehn

Suppressor Type

Type 2 Arrester

Maximum Voltage Rating

275 V

Mounting Type

DIN Rail

Maximum Surge Current

40kA

Series

DG

Length

54mm

Depth

66mm

Height

90mm

Dimensions

54 x 66 x 90mm

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+80°C

Zemlja podrijetla

Germany

Detalji o proizvodu

DEHNguard Modular Surge Arresters Type 2

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Informacije o stanju skladišta trenutno nisu dostupne.

Proverite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

RSD 45.592

Each (bez PDV-a)

RSD 54.710

Each (s PDV-om)

Dehn, DG Modular Surge Protector 275 V Maximum Voltage Rating 40kA Maximum Surge Current Type 2 Arrester

RSD 45.592

Each (bez PDV-a)

RSD 54.710

Each (s PDV-om)

Dehn, DG Modular Surge Protector 275 V Maximum Voltage Rating 40kA Maximum Surge Current Type 2 Arrester
Informacije o stanju skladišta trenutno nisu dostupne.

Kupujte na veliko

količinaJedinična cena
1 - 4RSD 45.592
5 - 9RSD 44.416
10 - 19RSD 43.763
20+RSD 41.542

Tehnička dokumentacija

Tehnički podaci

Brand

Dehn

Suppressor Type

Type 2 Arrester

Maximum Voltage Rating

275 V

Mounting Type

DIN Rail

Maximum Surge Current

40kA

Series

DG

Length

54mm

Depth

66mm

Height

90mm

Dimensions

54 x 66 x 90mm

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+80°C

Zemlja podrijetla

Germany

Detalji o proizvodu

DEHNguard Modular Surge Arresters Type 2

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.