Siemens 7 → 10 A SIRIUS 3RV Motor Protection Circuit Breaker
Tehnička dokumentacija
Tehnički podaci
Brand
SiemensCurrent Rating
7 → 10 A
Range
SIRIUS 3RV
Motor Protection Component
Circuit Breaker
Series
3RV1
Overall Length
90mm
Overall Width
45mm
Overall Depth
75mm
Minimum Operating Temperature
-20°C
Voltage Rating
690 V
Maximum Operating Temperature
+60°C
Breaking Capacity
100 kA
Number of Poles
3
Terminal Type
Screw
Size
90 x 45 x 75mm
Control Voltage
7 → 10 A
Zemlja podrijetla
Germany
Detalji o proizvodu
Three-pole, Motor Protective Circuit Breakers – 3RV10 Range
The 3RV10 current limiting motor starter protector is commonly known as a motor protection switch, as they are used for switching and protecting induction motors. Seimens 3RV Manual Motor Starters are optimized for load feeders. The motor circuit breakers are compact and offer long term stability.
Warning
This product is in obsolescence mode and is due for discontinuation by the manufacturer. We recommend that you review the alternative highlighted by the manufacturer. Alternatively, refer to the cross reference list in the Technical Reference section which highlights the upgrade path for your current generation of products.
Approvals
UL, CSA
Standards
IEC947, VDE0990, EN60947
Informacije o stanju skladišta trenutno nisu dostupne.
Proverite ponovno kasnije.
RSD 18.550
Each (bez PDV-a)
RSD 22.260
Each (s PDV-om)
1
RSD 18.550
Each (bez PDV-a)
RSD 22.260
Each (s PDV-om)
1
Tehnička dokumentacija
Tehnički podaci
Brand
SiemensCurrent Rating
7 → 10 A
Range
SIRIUS 3RV
Motor Protection Component
Circuit Breaker
Series
3RV1
Overall Length
90mm
Overall Width
45mm
Overall Depth
75mm
Minimum Operating Temperature
-20°C
Voltage Rating
690 V
Maximum Operating Temperature
+60°C
Breaking Capacity
100 kA
Number of Poles
3
Terminal Type
Screw
Size
90 x 45 x 75mm
Control Voltage
7 → 10 A
Zemlja podrijetla
Germany
Detalji o proizvodu
Three-pole, Motor Protective Circuit Breakers – 3RV10 Range
The 3RV10 current limiting motor starter protector is commonly known as a motor protection switch, as they are used for switching and protecting induction motors. Seimens 3RV Manual Motor Starters are optimized for load feeders. The motor circuit breakers are compact and offer long term stability.
Warning
This product is in obsolescence mode and is due for discontinuation by the manufacturer. We recommend that you review the alternative highlighted by the manufacturer. Alternatively, refer to the cross reference list in the Technical Reference section which highlights the upgrade path for your current generation of products.
Approvals
UL, CSA
Standards
IEC947, VDE0990, EN60947