ABB Frequency, Voltage Monitoring Relay, 1, 3 Phase, SPDT, 57.7 → 240 V ac, 99.9 → 415 V dc, DIN Rail

RS kataloški broj:: 876-2551brend: ABBProizvođački broj:: 1SVR560730R3402 CM-UFD.M33
brand-logo
Prikaži sve u Monitoring Relays

Tehnička dokumentacija

Tehnički podaci

Brand

ABB

Monitoring Application

Frequency, Voltage

Electrical Phase

1, 3

Contact Configuration

SPDT

Voltage Sensing Range

57.7 → 240 V ac, 99.9 → 415 V dc

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Time Delay

±20ms

Frequency Sensing Range

40 → 70Hz

Series

CM-UFD

Height

90mm

Maximum Frequency Sensed

70Hz

Length

108mm

Minimum Voltage Sensed

0V ac

Minimum Frequency Sensed

40Hz

Operating Temperature Range

-20 → +60°C

Frequency Sensitivity

Overfrequency, Underfrequency

Terminal Type

Screw

Special Features

Monitoring of ROCOF (Rate of Change of Frequency), Multiline Backlit LCD Display, Password Setting Protection

Number of Poles

1

Dimensions

108 x 67 x 90mm

Current Range

6.4mA

Minimum Operating Temperature

-20°C

Width

67mm

Maximum Operating Temperature

+60°C

Maximum Voltage Sensed

415V dc

Maximum Temperature Sensed

80°C

Detalji o proizvodu

CM-UFD Grid Feeding Relays

The expertly designed CM-UFD range of grid feeding relays ensures safe and reliable monitoring of numerous grid parameters when feeding energy into the public grid.

Informacije o stanju skladišta trenutno nisu dostupne.

Proverite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

P.O.A.

ABB Frequency, Voltage Monitoring Relay, 1, 3 Phase, SPDT, 57.7 → 240 V ac, 99.9 → 415 V dc, DIN Rail

P.O.A.

ABB Frequency, Voltage Monitoring Relay, 1, 3 Phase, SPDT, 57.7 → 240 V ac, 99.9 → 415 V dc, DIN Rail
Informacije o stanju skladišta trenutno nisu dostupne.

Tehnička dokumentacija

Tehnički podaci

Brand

ABB

Monitoring Application

Frequency, Voltage

Electrical Phase

1, 3

Contact Configuration

SPDT

Voltage Sensing Range

57.7 → 240 V ac, 99.9 → 415 V dc

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Time Delay

±20ms

Frequency Sensing Range

40 → 70Hz

Series

CM-UFD

Height

90mm

Maximum Frequency Sensed

70Hz

Length

108mm

Minimum Voltage Sensed

0V ac

Minimum Frequency Sensed

40Hz

Operating Temperature Range

-20 → +60°C

Frequency Sensitivity

Overfrequency, Underfrequency

Terminal Type

Screw

Special Features

Monitoring of ROCOF (Rate of Change of Frequency), Multiline Backlit LCD Display, Password Setting Protection

Number of Poles

1

Dimensions

108 x 67 x 90mm

Current Range

6.4mA

Minimum Operating Temperature

-20°C

Width

67mm

Maximum Operating Temperature

+60°C

Maximum Voltage Sensed

415V dc

Maximum Temperature Sensed

80°C

Detalji o proizvodu

CM-UFD Grid Feeding Relays

The expertly designed CM-UFD range of grid feeding relays ensures safe and reliable monitoring of numerous grid parameters when feeding energy into the public grid.