Bourns, 1250 Surge Arrester 600 V ac Maximum Voltage Rating 50kA Maximum Surge Current 3 Pole Protector

RS kataloški broj:: 172-9928brend: BournsProizvođački broj:: 1250-3S-400
brand-logo
Prikaži sve u Surge Suppressor Units

Tehnička dokumentacija

Tehnički podaci

Brand

Bourns

Suppressor Type

3 Pole Protector

Maximum Voltage Rating

600 V ac

Mounting Type

DIN Rail

Maximum Surge Current

50kA

Series

1250

Length

54mm

Depth

67mm

Height

90mm

Dimensions

54 x 67 x 90mm

Minimum Operating Temperature

-50°C

Maximum Operating Temperature

+85°C

Zemlja podrijetla

China

Detalji o proizvodu

Bourns 1250 series Surge Protection Devices

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Informacije o stanju skladišta trenutno nisu dostupne.

Proverite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

RSD 58.001,896

komad (u kutiji od 3) (bez PDV-a)

RSD 69.602,275

komad (u kutiji od 3) (s PDV-om)

Bourns, 1250 Surge Arrester 600 V ac Maximum Voltage Rating 50kA Maximum Surge Current 3 Pole Protector

RSD 58.001,896

komad (u kutiji od 3) (bez PDV-a)

RSD 69.602,275

komad (u kutiji od 3) (s PDV-om)

Bourns, 1250 Surge Arrester 600 V ac Maximum Voltage Rating 50kA Maximum Surge Current 3 Pole Protector
Informacije o stanju skladišta trenutno nisu dostupne.

Tehnička dokumentacija

Tehnički podaci

Brand

Bourns

Suppressor Type

3 Pole Protector

Maximum Voltage Rating

600 V ac

Mounting Type

DIN Rail

Maximum Surge Current

50kA

Series

1250

Length

54mm

Depth

67mm

Height

90mm

Dimensions

54 x 67 x 90mm

Minimum Operating Temperature

-50°C

Maximum Operating Temperature

+85°C

Zemlja podrijetla

China

Detalji o proizvodu

Bourns 1250 series Surge Protection Devices

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.