Dehn, DG Surge Protection Plug 275 V ac, 350 V dc Maximum Voltage Rating 40kA Maximum Surge Current Surge Arrester

RS kataloški broj:: 768-1772brend: DehnProizvođački broj:: DG MOD 275
brand-logo
Prikaži sve u Surge Suppressor Units

Tehnička dokumentacija

Tehnički podaci

Brand

Dehn

Suppressor Type

Surge Arrester Protection Module

Maximum Voltage Rating

275 V ac, 350 V dc

Mounting Type

Plug In

Maximum Surge Current

40kA

Series

DG

Length

45mm

Depth

18mm

Height

51mm

Dimensions

45 x 18 x 51mm

Zemlja podrijetla

Germany

Detalji o proizvodu

DEHNguard and DEHNrail Replacement Plugin Modules

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Informacije o stanju skladišta trenutno nisu dostupne.

Proverite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

RSD 21.163

Each (bez PDV-a)

RSD 25.395

Each (s PDV-om)

Dehn, DG Surge Protection Plug 275 V ac, 350 V dc Maximum Voltage Rating 40kA Maximum Surge Current Surge Arrester

RSD 21.163

Each (bez PDV-a)

RSD 25.395

Each (s PDV-om)

Dehn, DG Surge Protection Plug 275 V ac, 350 V dc Maximum Voltage Rating 40kA Maximum Surge Current Surge Arrester
Informacije o stanju skladišta trenutno nisu dostupne.

Kupujte na veliko

količinaJedinična cena
1 - 4RSD 21.163
5 - 9RSD 20.510
10 - 24RSD 20.248
25+RSD 19.334

Tehnička dokumentacija

Tehnički podaci

Brand

Dehn

Suppressor Type

Surge Arrester Protection Module

Maximum Voltage Rating

275 V ac, 350 V dc

Mounting Type

Plug In

Maximum Surge Current

40kA

Series

DG

Length

45mm

Depth

18mm

Height

51mm

Dimensions

45 x 18 x 51mm

Zemlja podrijetla

Germany

Detalji o proizvodu

DEHNguard and DEHNrail Replacement Plugin Modules

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.