Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max

RS kataloški broj:: 410-517brend: ParkerProizvođački broj:: PRT-A10
brand-logo
Prikaži sve u Pneumatic Timers

Tehnička dokumentacija

Tehnički podaci

Brand

Parker

Maximum Time

30s

Minimum Time

0.1s

Maximum Operating Temperature

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-15°C

Detalji o proizvodu

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

Informacije o stanju skladišta trenutno nisu dostupne.

Proverite ponovno kasnije.

Informacije o stanju skladišta trenutno nisu dostupne.

RSD 47.812

Each (bez PDV-a)

RSD 57.375

Each (s PDV-om)

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max

RSD 47.812

Each (bez PDV-a)

RSD 57.375

Each (s PDV-om)

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max
Informacije o stanju skladišta trenutno nisu dostupne.

Kupujte na veliko

količinaJedinična cena
1 - 4RSD 47.812
5+RSD 46.506

Tehnička dokumentacija

Tehnički podaci

Brand

Parker

Maximum Time

30s

Minimum Time

0.1s

Maximum Operating Temperature

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-15°C

Detalji o proizvodu

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.