Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max

RS kataloški broj:: 410-517brend: ParkerProizvođački broj:: PRT-A10
brand-logo
Prikaži sve u Pneumatic Timers

Tehnička dokumentacija

Tehnički podaci

Brand

Parker

Maximum Time

30s

Minimum Time

0.1s

Maximum Operating Temperature

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-15°C

Detalji o proizvodu

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

Možda će vas interesovati

RSD 52.656

RSD 52.656 Each (bez PDV-a)

RSD 63.188

RSD 63.188 Each (s PDV-om)

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max

RSD 52.656

RSD 52.656 Each (bez PDV-a)

RSD 63.188

RSD 63.188 Each (s PDV-om)

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max

Informacije o stanju skladišta trenutno nisu dostupne.

Informacije o stanju skladišta trenutno nisu dostupne.

količinaJedinična cena
1 - 4RSD 52.656
5+RSD 51.277
Možda će vas interesovati

Tehnička dokumentacija

Tehnički podaci

Brand

Parker

Maximum Time

30s

Minimum Time

0.1s

Maximum Operating Temperature

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-15°C

Detalji o proizvodu

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

Možda će vas interesovati