Tehnička dokumentacija
Tehnički podaci
Automotive Standard
AEC-Q200
Minimum Operating Temperature
-55°C
Power Rating
0.125W
Maximum Operating Temperature
+155°C
Technology
Thick Film
Tolerance
±1%
Temperature Coefficient
±100ppm/°C
Resistance
4.7kΩ
Series
CRCW
Package/Case
0805 (2012M)
Brand
VishayDetalji o proizvodu
ICP Series 3 Phase Monitoring Relay
Hiquel ICP monitors phase-failure, phase-sequence and phase-asymmetry for supplies with or without neutral. Thresholds for alarm functions, alarm reaction time and phase-asymmetry can be easily adjusted using the rotary switches on the front plate. When monitoring a 3 phase & neutral system, the neutral must be connected to the N-terminal and the monitoring function must be enabled by a dip switch.
Hiquel in-Case Series Monitoring Relays
HIQUEL in-Case series, an integrated range of industrial monitoring and timing relays in a compact 22.5 mm DIN Rail case. Designed with emphasis on flexibility and incorporating a new micro-controller, just four monitoring relays offer a complete range. Featuring single phase current and voltage, 3 phase voltage, and thermistor monitoring. With all popular functions, combinations and options selected by switches.
Informacije o stanju skladišta trenutno nisu dostupne.
Provjerite ponovno kasnije.
€ 0,03
Each (In a Pack of 50) (bez PDV-a)
€ 0,035
Each (In a Pack of 50) (s PDV-om)
Standard
50
€ 0,03
Each (In a Pack of 50) (bez PDV-a)
€ 0,035
Each (In a Pack of 50) (s PDV-om)
Standard
50
Kupujte na veliko
količina | Jedinična cijena | Po pakovanje |
---|---|---|
50 - 2450 | € 0,03 | € 1,50 |
2500 - 4950 | € 0,02 | € 1,00 |
5000+ | € 0,01 | € 0,50 |
Tehnička dokumentacija
Tehnički podaci
Automotive Standard
AEC-Q200
Minimum Operating Temperature
-55°C
Power Rating
0.125W
Maximum Operating Temperature
+155°C
Technology
Thick Film
Tolerance
±1%
Temperature Coefficient
±100ppm/°C
Resistance
4.7kΩ
Series
CRCW
Package/Case
0805 (2012M)
Brand
VishayDetalji o proizvodu
ICP Series 3 Phase Monitoring Relay
Hiquel ICP monitors phase-failure, phase-sequence and phase-asymmetry for supplies with or without neutral. Thresholds for alarm functions, alarm reaction time and phase-asymmetry can be easily adjusted using the rotary switches on the front plate. When monitoring a 3 phase & neutral system, the neutral must be connected to the N-terminal and the monitoring function must be enabled by a dip switch.
Hiquel in-Case Series Monitoring Relays
HIQUEL in-Case series, an integrated range of industrial monitoring and timing relays in a compact 22.5 mm DIN Rail case. Designed with emphasis on flexibility and incorporating a new micro-controller, just four monitoring relays offer a complete range. Featuring single phase current and voltage, 3 phase voltage, and thermistor monitoring. With all popular functions, combinations and options selected by switches.