Tehnički podaci
Proizvođač
BurkertProduct Type
Flow Controller
Terminal Type
Cable Plug
Control Output
PNP
Mount Type
Compact
Maximum Pipe Diameter
65mm
Minimum Operating Temperature
-15°C
Maximum Supply Voltage
36V dc
Maximum Operating Temperature
60°C
Hazardous Area Certification
ATEX
Standards/Approvals
EMC
Series
8030
Current Rating
100mA
Zemlja podrijetla
France
Detalji o proizvodu
The Burkert flow transmitter + sensor has an open collector (PNP/NPN) type output and cable plug electrical connection device. It is designed to measure the continuous flow of liquids. Its operating voltage rating ranges between 12VDC and 36VDC. This sensor produces a signal which can be transmitted and processed enabling the end-user to get a flow measurement. The division is performed by measuring the pulses for the required unit of flow (litres per min.) and then, by the use of four rotary switches on the divider unit (discontinued) - that it is on top of the transmitter to divide signals enabling the output to be tailored to individual requirements. The correct dividing factor can be set up to give the required pulses out for the flow rate.
Informacije o stanju skladišta trenutno nisu dostupne.
€ 251,85
€ 251,85 komadno (bez PDV-a)
€ 314,81
€ 314,81 komadno (s PDV-om)
1
€ 251,85
€ 251,85 komadno (bez PDV-a)
€ 314,81
€ 314,81 komadno (s PDV-om)
Informacije o stanju skladišta trenutno nisu dostupne.
1
Tehnička dokumentacija
Tehnički podaci
Proizvođač
BurkertProduct Type
Flow Controller
Terminal Type
Cable Plug
Control Output
PNP
Mount Type
Compact
Maximum Pipe Diameter
65mm
Minimum Operating Temperature
-15°C
Maximum Supply Voltage
36V dc
Maximum Operating Temperature
60°C
Hazardous Area Certification
ATEX
Standards/Approvals
EMC
Series
8030
Current Rating
100mA
Zemlja podrijetla
France
Detalji o proizvodu
The Burkert flow transmitter + sensor has an open collector (PNP/NPN) type output and cable plug electrical connection device. It is designed to measure the continuous flow of liquids. Its operating voltage rating ranges between 12VDC and 36VDC. This sensor produces a signal which can be transmitted and processed enabling the end-user to get a flow measurement. The division is performed by measuring the pulses for the required unit of flow (litres per min.) and then, by the use of four rotary switches on the divider unit (discontinued) - that it is on top of the transmitter to divide signals enabling the output to be tailored to individual requirements. The correct dividing factor can be set up to give the required pulses out for the flow rate.