Aim-TTi 1908P Bench Digital Multimeter True RMS, 10 A Max, 10 A Max

RS kataloški broj:: 123-8854robna marka: Aim-TTiProizvođački broj:: 1908PDistrelec broj artikla: 300-77-093
brand-logo
Prikaži sve u Multimetri

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Aim-TTi

Product Type

Multimeter

Multimeter Type

Bench

Model Number

1908P

Resistance Resolution

1mΩ

Display Type

Digital

Functions Measured

Temperature, DC Voltage, AC Voltage, Capacitance, DC Current, Frequency, Resistance, AC Current

Maximum DC Voltage Measurement

1000V

Maximum DC Current Measurement

10A

Maximum Resistance Measurement

1kΩ

Maximum AC Current Measurement

10A

True RMS

Yes

DC Current Accuracy

0.05 %

AC Voltage Accuracy

0.3 %

AC Current Accuracy

0.35 %

DC Voltage Accuracy

0.02 %

DC Current Resolution

100nA dc

AC Current Resolution

100nA

DC Voltage Resolution

1 μV

Maximum Frequency

100kHz

Minimum Operating Temperature

5°C

Resistance Measurement Accuracy

±0.05 %

Maximum Operating Temperature

40°C

Length

260mm

Width

235 mm

Height

88mm

Weight

2kg

Standards/Approvals

No

Safety Category Level

CAT II

Battery Type

Rechargeable Ni-MH

Safety Category Voltage

600V

Zemlja podrijetla

United Kingdom

Detalji o proizvodu

Aim-TTI 1908P Series Dual Measurement Bench Multimeter

Aim-TTi 1908 Series is a dual measurement, dual display bench-top/portable multimeter. It features continuity and diode test, automatic or manual ranging, linear scaling with offset, dB measurements, limits comparison, percentage deviation (%), min-max storage, power measurement in watts or VA, automatic data logging and external triggering. The logger function can store up to 500 readings from the main display in non-volatile memory. The two displays can be used to display a measurement along with the selected range (e.g. 100 Vdc), a measurement in two different units (e.g. AC volts and dBm), the result of a calculated function (e.g. value and % deviation), two parameters of one signal (e.g. AC and DC volts) or two different signals (e.g. AC volts and DC current). Software 1908-PC Link provides remote control of main functions and logging function with graphical and tabular displays (logged data can be exported to a CSV file). Model 1908P can be remotely controlled via its RS232, USB or LAN interface. Model 1908 (non ’P’) can only be controlled via USB.
For an optional GPIB module see stock number 144-5481.

Supplied with

IVI driver, LV/CVI driver, USB driver

Standards

EN61010-1, EN61010-2-030 & EN61010-2-033, EN61326-1 EMC

Možda će vas zanimati

Informacije o stanju skladišta trenutno nisu dostupne.

Cijena na upit

Aim-TTi 1908P Bench Digital Multimeter True RMS, 10 A Max, 10 A Max

Vrsta kalibracije

Cijena na upit

Aim-TTi 1908P Bench Digital Multimeter True RMS, 10 A Max, 10 A Max

Informacije o stanju skladišta trenutno nisu dostupne.

Vrsta kalibracije

Možda će vas zanimati

Tehnička dokumentacija

Tehnički podaci

Proizvođač

Aim-TTi

Product Type

Multimeter

Multimeter Type

Bench

Model Number

1908P

Resistance Resolution

1mΩ

Display Type

Digital

Functions Measured

Temperature, DC Voltage, AC Voltage, Capacitance, DC Current, Frequency, Resistance, AC Current

Maximum DC Voltage Measurement

1000V

Maximum DC Current Measurement

10A

Maximum Resistance Measurement

1kΩ

Maximum AC Current Measurement

10A

True RMS

Yes

DC Current Accuracy

0.05 %

AC Voltage Accuracy

0.3 %

AC Current Accuracy

0.35 %

DC Voltage Accuracy

0.02 %

DC Current Resolution

100nA dc

AC Current Resolution

100nA

DC Voltage Resolution

1 μV

Maximum Frequency

100kHz

Minimum Operating Temperature

5°C

Resistance Measurement Accuracy

±0.05 %

Maximum Operating Temperature

40°C

Length

260mm

Width

235 mm

Height

88mm

Weight

2kg

Standards/Approvals

No

Safety Category Level

CAT II

Battery Type

Rechargeable Ni-MH

Safety Category Voltage

600V

Zemlja podrijetla

United Kingdom

Detalji o proizvodu

Aim-TTI 1908P Series Dual Measurement Bench Multimeter

Aim-TTi 1908 Series is a dual measurement, dual display bench-top/portable multimeter. It features continuity and diode test, automatic or manual ranging, linear scaling with offset, dB measurements, limits comparison, percentage deviation (%), min-max storage, power measurement in watts or VA, automatic data logging and external triggering. The logger function can store up to 500 readings from the main display in non-volatile memory. The two displays can be used to display a measurement along with the selected range (e.g. 100 Vdc), a measurement in two different units (e.g. AC volts and dBm), the result of a calculated function (e.g. value and % deviation), two parameters of one signal (e.g. AC and DC volts) or two different signals (e.g. AC volts and DC current). Software 1908-PC Link provides remote control of main functions and logging function with graphical and tabular displays (logged data can be exported to a CSV file). Model 1908P can be remotely controlled via its RS232, USB or LAN interface. Model 1908 (non ’P’) can only be controlled via USB.
For an optional GPIB module see stock number 144-5481.

Supplied with

IVI driver, LV/CVI driver, USB driver

Standards

EN61010-1, EN61010-2-030 & EN61010-2-033, EN61326-1 EMC