Tehnička dokumentacija
Tehnički podaci
Proizvođač
HartingProduct Type
Hinged Frame
Accessory Type
Metal Frame
Size
10B
Cable Entry Angle
Top
Boja
Grey
Number of Contacts
2
Series
HAN Modular
For Use With
Standard Han Hoods and Housings
Material
Die Cast Zinc
Standards/Approvals
CSA, DNV GL, UL
Thread Size
M3
Minimum Wire Size mm²
4mm²
Maximum Wire Size mm²
10mm²
Zemlja podrijetla
Germany
Detalji o proizvodu
This hinged frame provides a top-entry metal mounting solution for modular connector hoods and housings. Designed for three-module A to C arrangements, it delivers a Durable Interface between standard Han hoods and enclosures. The unit is intended for industrial installations requiring a hinged access point and supports both power and signal conductor connections within defined conductor cross-sections.
It is specified to operate between -40 to +125°C.
It is approved under UL and CSA standards and has DNV GL recognition.
Signal-side conductor cross-sections are specified as 1 to 2.5mm².
Recommended tightening torques are 0.8 Nm for M3 and 1.2 Nm for M4 PE screws.
The 1 module is for use with hoods and housings from range 2 – the Harting 10A Series (see stock no. 181-0662 which is typical of that range)
Informacije o stanju skladišta trenutno nisu dostupne.
€ 36,32
€ 36,32 komadno (bez PDV-a)
1
€ 36,32
€ 36,32 komadno (bez PDV-a)
Informacije o stanju skladišta trenutno nisu dostupne.
1
Tehnička dokumentacija
Tehnički podaci
Proizvođač
HartingProduct Type
Hinged Frame
Accessory Type
Metal Frame
Size
10B
Cable Entry Angle
Top
Boja
Grey
Number of Contacts
2
Series
HAN Modular
For Use With
Standard Han Hoods and Housings
Material
Die Cast Zinc
Standards/Approvals
CSA, DNV GL, UL
Thread Size
M3
Minimum Wire Size mm²
4mm²
Maximum Wire Size mm²
10mm²
Zemlja podrijetla
Germany
Detalji o proizvodu
This hinged frame provides a top-entry metal mounting solution for modular connector hoods and housings. Designed for three-module A to C arrangements, it delivers a Durable Interface between standard Han hoods and enclosures. The unit is intended for industrial installations requiring a hinged access point and supports both power and signal conductor connections within defined conductor cross-sections.
It is specified to operate between -40 to +125°C.
It is approved under UL and CSA standards and has DNV GL recognition.
Signal-side conductor cross-sections are specified as 1 to 2.5mm².
Recommended tightening torques are 0.8 Nm for M3 and 1.2 Nm for M4 PE screws.
The 1 module is for use with hoods and housings from range 2 – the Harting 10A Series (see stock no. 181-0662 which is typical of that range)