PR Electronics 2 Channel Galvanic Barrier, Pulse, IECEx, ATEX

RS kataloški broj:: 136-8696robna marka: PR ElectronicsProizvođački broj:: 5202B4
brand-logo
Prikaži sve u Zener & Galvanic Barriers

Tehnička dokumentacija

Tehnički podaci

Proizvođač

PR Electronics

Number of Channels

2

Product Type

Galvanic Barrier

Barrier Type

Galvanic Barrier

Mount Type

DIN Rail

Hazardous Area Certification

IECEx, ATEX

Terminal Type

Screw

IP Rating

IP20

Supply Voltage

19.2 to 300 V dc, 21.6 to 253 V ac

Maximum Safety Current

400mA

Minimum Operating Temperature

-20°C

Signal Type

Pulse

Maximum Safety Voltage

300V

Maximum Operating Temperature

60°C

Standards/Approvals

TR-CU 020/2011, 2014/35/EU, EN 60947-5-6, 2014/30/EU, PELV/SELV IEC 61140

Series

5200

Zemlja podrijetla

Denmark

Detalji o proizvodu

PR Electronics 5202B Ex Pulse Isolator

PR Electronics 5202B pulse isolator for transmission of signals to the safe area from NAMUR sensors installed in hazardous areas. This signal conditioning isolator measures one or more pulse inputs and provides an identical number of isolated pulse outputs. The PR 5202B uses transformer and optical isolation techniques to provide 3.75 kVac galvanic isolation between the input, output and power terminals. The high level of electrical isolation means that input pulses sensed at the 5202B are not electrically connected to the output pulse. The 5202B has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
Besides providing isolation, the PR 5202B is a barrier. This means that the module can make an intrinsically safe measurement of contacts and NAMUR sensors mounted in a zone 0/ Division 1 explosion hazard area. The PR 5202B limits the level of energy present at the contact or the NAMUR sensor to a low intrinsically safe level, thereby preventing ignition of a flammable atmosphere around the sensor – even if the sensor or the cable is damaged.

PR Electronics - Ex Interfaces

Zamisliti. Stvoriti. Surađivati

PRIDRUŽITE SE BESPLATNO

Bez skrivenih naknada!

design-spark
design-spark
  • Preuzmite i koristite naš softver DesignSpark za svoje PCB i 3D mehaničke dizajne
  • Pregledajte i doprinesite sadržaju internet stranice i foruma
  • Preuzmite 3D modele, sheme i otiske s više od milijun proizvoda
Kliknite ovdje kako biste saznali više

Informacije o stanju skladišta trenutno nisu dostupne.

€ 385,52

€ 385,52 komadno (bez PDV-a)

€ 481,90

€ 481,90 komadno (s PDV-om)

PR Electronics 2 Channel Galvanic Barrier, Pulse, IECEx, ATEX

€ 385,52

€ 385,52 komadno (bez PDV-a)

€ 481,90

€ 481,90 komadno (s PDV-om)

PR Electronics 2 Channel Galvanic Barrier, Pulse, IECEx, ATEX

Informacije o stanju skladišta trenutno nisu dostupne.

Zamisliti. Stvoriti. Surađivati

PRIDRUŽITE SE BESPLATNO

Bez skrivenih naknada!

design-spark
design-spark
  • Preuzmite i koristite naš softver DesignSpark za svoje PCB i 3D mehaničke dizajne
  • Pregledajte i doprinesite sadržaju internet stranice i foruma
  • Preuzmite 3D modele, sheme i otiske s više od milijun proizvoda
Kliknite ovdje kako biste saznali više

Tehnička dokumentacija

Tehnički podaci

Proizvođač

PR Electronics

Number of Channels

2

Product Type

Galvanic Barrier

Barrier Type

Galvanic Barrier

Mount Type

DIN Rail

Hazardous Area Certification

IECEx, ATEX

Terminal Type

Screw

IP Rating

IP20

Supply Voltage

19.2 to 300 V dc, 21.6 to 253 V ac

Maximum Safety Current

400mA

Minimum Operating Temperature

-20°C

Signal Type

Pulse

Maximum Safety Voltage

300V

Maximum Operating Temperature

60°C

Standards/Approvals

TR-CU 020/2011, 2014/35/EU, EN 60947-5-6, 2014/30/EU, PELV/SELV IEC 61140

Series

5200

Zemlja podrijetla

Denmark

Detalji o proizvodu

PR Electronics 5202B Ex Pulse Isolator

PR Electronics 5202B pulse isolator for transmission of signals to the safe area from NAMUR sensors installed in hazardous areas. This signal conditioning isolator measures one or more pulse inputs and provides an identical number of isolated pulse outputs. The PR 5202B uses transformer and optical isolation techniques to provide 3.75 kVac galvanic isolation between the input, output and power terminals. The high level of electrical isolation means that input pulses sensed at the 5202B are not electrically connected to the output pulse. The 5202B has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
Besides providing isolation, the PR 5202B is a barrier. This means that the module can make an intrinsically safe measurement of contacts and NAMUR sensors mounted in a zone 0/ Division 1 explosion hazard area. The PR 5202B limits the level of energy present at the contact or the NAMUR sensor to a low intrinsically safe level, thereby preventing ignition of a flammable atmosphere around the sensor – even if the sensor or the cable is damaged.

PR Electronics - Ex Interfaces

Zamisliti. Stvoriti. Surađivati

PRIDRUŽITE SE BESPLATNO

Bez skrivenih naknada!

design-spark
design-spark
  • Preuzmite i koristite naš softver DesignSpark za svoje PCB i 3D mehaničke dizajne
  • Pregledajte i doprinesite sadržaju internet stranice i foruma
  • Preuzmite 3D modele, sheme i otiske s više od milijun proizvoda
Kliknite ovdje kako biste saznali više