RS PRO, MAXX Surge Suppressor Unit 253V Maximum Voltage Rating 6.5 kA Maximum Surge Current EMC Filter

RS kataloški broj:: 206-7926robna marka: RS PRO
brand-logo
Prikaži sve u Surge Suppressor Units

Tehnička dokumentacija

Tehnički podaci

Proizvođač

RS Pro

Product Type

Surge Suppressor Unit

Suppressor Type

EMC Filter

Maximum Voltage

253V

Mount Type

DIN Rail

Maximum Surge Current

6.5kA

Series

MAXX

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

85°C

Standards/Approvals

ANSI/ESD S20.20:2014

Hazardous Area Certification

No

Detalji o proizvodu

Surge & Noise Suppressor, MAxx / D Series

Combined surge and RFI filter units

Warning

Will not pass a 500V insulation test.

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Informacije o stanju skladišta trenutno nisu dostupne.

€ 379,62

€ 379,62 komadno (bez PDV-a)

€ 474,52

€ 474,52 komadno (s PDV-om)

RS PRO, MAXX Surge Suppressor Unit 253V Maximum Voltage Rating 6.5 kA Maximum Surge Current EMC Filter

€ 379,62

€ 379,62 komadno (bez PDV-a)

€ 474,52

€ 474,52 komadno (s PDV-om)

RS PRO, MAXX Surge Suppressor Unit 253V Maximum Voltage Rating 6.5 kA Maximum Surge Current EMC Filter

Informacije o stanju skladišta trenutno nisu dostupne.

količinajedinična cijena
1 - 1€ 379,62
2 - 4€ 369,62
5+€ 365,18

Tehnička dokumentacija

Tehnički podaci

Proizvođač

RS Pro

Product Type

Surge Suppressor Unit

Suppressor Type

EMC Filter

Maximum Voltage

253V

Mount Type

DIN Rail

Maximum Surge Current

6.5kA

Series

MAXX

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

85°C

Standards/Approvals

ANSI/ESD S20.20:2014

Hazardous Area Certification

No

Detalji o proizvodu

Surge & Noise Suppressor, MAxx / D Series

Combined surge and RFI filter units

Warning

Will not pass a 500V insulation test.

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.