Tehnička dokumentacija
Tehnički podaci
Proizvođač
TDK-LambdaProduct Type
Switching Power Supply
Maximum Output Voltage
19V dc
Number of Outputs
1
Mount Type
Panel
Power
600W
Minimum Operating Temperature
-20°C
SMPS Output Current
8.4A
Maximum Operating Temperature
70°C
Length
198mm
Depth
198mm
Weight
440g
Standards/Approvals
CE, EN 55022-B, FCC-B, IEC 61000-4-11, IEC 61000-4-2 (lv 2,3), IEC 61000-4-3 (lv3), IEC 61000-4-4 (lv 3), IEC 61000-4-5 (lv 3,4), IEC 61000-4-6 (lv 3), IEC 61000-4-8 (lv 4), IEC/UL/CSA/EN 62368-1
Width
128mm
Efficiency
90%
Maximum Input Voltage
8.4V ac
Series
CUS600M
Output Current
8.4A
Hazardous Area Certification
No
Minimum Input Voltage
8.4V ac
Zemlja podrijetla
China
Detalji o proizvodu
The TDK-Lambda compact CUS600M is packaged in the industry standard 3x5 footprint and can deliver 600W with forced air or 400W with a 600W peak power with convection cooling. With Medical & ITE certifications, the unit can be used in both Class I & Class II (no ground wire) applications, and meets Class B Conducted and Radiated EMI. A 5V 2A standby voltage, remote on/off, remote sense and a Power Good signal are fitted as standard. Other options, including an internal fan, are available.
Informacije o stanju skladišta trenutno nisu dostupne.
€ 303,75
€ 303,75 komadno (bez PDV-a)
1
€ 303,75
€ 303,75 komadno (bez PDV-a)
Informacije o stanju skladišta trenutno nisu dostupne.
1
| količina | jedinična cijena |
|---|---|
| 1 - 4 | € 303,75 |
| 5+ | € 298,85 |
Tehnička dokumentacija
Tehnički podaci
Proizvođač
TDK-LambdaProduct Type
Switching Power Supply
Maximum Output Voltage
19V dc
Number of Outputs
1
Mount Type
Panel
Power
600W
Minimum Operating Temperature
-20°C
SMPS Output Current
8.4A
Maximum Operating Temperature
70°C
Length
198mm
Depth
198mm
Weight
440g
Standards/Approvals
CE, EN 55022-B, FCC-B, IEC 61000-4-11, IEC 61000-4-2 (lv 2,3), IEC 61000-4-3 (lv3), IEC 61000-4-4 (lv 3), IEC 61000-4-5 (lv 3,4), IEC 61000-4-6 (lv 3), IEC 61000-4-8 (lv 4), IEC/UL/CSA/EN 62368-1
Width
128mm
Efficiency
90%
Maximum Input Voltage
8.4V ac
Series
CUS600M
Output Current
8.4A
Hazardous Area Certification
No
Minimum Input Voltage
8.4V ac
Zemlja podrijetla
China
Detalji o proizvodu
The TDK-Lambda compact CUS600M is packaged in the industry standard 3x5 footprint and can deliver 600W with forced air or 400W with a 600W peak power with convection cooling. With Medical & ITE certifications, the unit can be used in both Class I & Class II (no ground wire) applications, and meets Class B Conducted and Radiated EMI. A 5V 2A standby voltage, remote on/off, remote sense and a Power Good signal are fitted as standard. Other options, including an internal fan, are available.